The boiler flue gas outlet must be installed with the flue gas non-return valve kit, which ensures correct operation of the appli-
ance and facilitates its maintenance operations.
Furthermore, the safety sticker must be affixed on the front casing. This sticker is contained in the appropriate Kit C(10) C(12), which
contains the additional exhaust flue gas non-return valve, necessary for the pressurised collective flues.
The sticker indicates the following information in language:
It is advisable to affix the sticker in a clearly visible position on the front casing.
- The installation of this boiler is of type C(10) or C(12).
- Before proceeding with maintenance operations, it is crucial to read the instructions provided in the manual.
- Parameter “Min” relating to the fan rotation speed must be set to 1.
When the sealed chamber is opened, combustion products may escape even when the boiler is turned off.
Maximum Immergas flue duct extensions for installation in collective flue
- Flue ducts Ø 80/80: 10 1 metre intake terminal
- Flue ducts Ø 80/125: 7.7 metres
1.23 DUCTING OF FLUES OR TECHNICAL SLOTS
Ducting is an operation through which, via the introduction of one or more relevant pipes, one achieves a system for the evacuation of the
combustion products of a gas appliance, made up from the coupling of an existing or new ducting pipe with a chimney, flue or technical
slot (also in new buildings) (Fig. 37).
Ducting requires ducts declared to be suitable for the purpose by the manufacturer, following the installation and user instructions,
provided by the manufacturer and the requirements of the regulations in force.
Immergas ducting systems
The Ø 60 rigid, Ø 50 and Ø 80 flexible and Ø 80 rigid “Green Range” ducting systems must only be used for domestic use and
with Immergas condensing boilers.
In any case, ducting operations must respect the provisions contained in the standard and in current technical regulations; in particular,
the declaration of conformity must be compiled at the end of work and on commissioning of the ducted system.
The instructions in the project or technical report must likewise be followed, in cases provided for by the standard and current technical
regulations.
To guarantee reliability and operation over time of the ducting system, make sure:
- it is used in average atmospheric and environmental conditions, according to current regulations (absence of combustion products,
dusts or gases that can alter the normal thermophysical or chemical conditions; existence of temperatures coming within the standard
range of daily variation, etc.).
- Installation and maintenance must be performed according to the indications supplied by the manufacturer included with the “green
range” ducting system chosen and in compliance with the regulations in force.
- The maximum length specified by the manufacturer must be respected; in this regard:
• The max. possible length of the Ø 60 flexible ducting vertical section is equal to 22 m. This length is obtained considering the com-
plete Ø 80 exhaust terminal, 1 m of Ø 80 pipe in exhaust, two 90° Ø 80 bends at boiler outlet.
• The max. possible length of the Ø 80 flexible ducting vertical section is equal to 18 m. This length is obtained considering the Ø 80
complete exhaust terminal, 1 m of Ø 80 pipe in exhaust, two 90° Ø 80 bends at boiler outlet for connecting to the ducting system and
two direction changes of the flexible hose inside the chimney/technical slot.
• The max. possible length of the Ø 80 flexible ducting vertical section is equal to 6.7 m. This length is obtained considering the Ø 80
complete exhaust terminal, 1 m of Ø 80 pipe in exhaust, two 90° Ø 80 bends at boiler outlet for connecting to the ducting system and
two direction changes of the flexible hose inside the chimney/technical slot.
- The maximum length that the Ø 50 flexible ducted tract can run is equal to 13 m straight. This length is obtained considering the
complete Ø 80 exhaust terminal, 1 m of Ø 80 pipe in exhaust, two 90° Ø 80 bends at boiler outlet and the reduced Ø 80/50 T fitting.