34
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
3.20 COMBUSTION PARAMETERS.
G20
G30
G31
Supply pressure
mbar (mm H
2
O)
20 (204)
29 (296)
37 (377)
Victrix X 12 2 I
Gas nozzle diameter
mm
3.70
2.80
2.80
Flue flow rate at nominal heat output
kg/h
19
17
20
Flue flow rate at min heat output
kg/h
3
3
3
CO
2
at Nom Q./Min.
%
9.50 / 8.85
12.50 / 11.60
10.60 / 10.20
CO with 0% O
2
at Nom Q /Min.
ppm
110 / 4
440 / 4
115 / 1
NO
X
with 0% O
2
at Nom Q /Min.
mg/kWh
48 / 13
185 / 20
85 / 25
Flue temperature at nominal output
°C
56
63
57
Flue temperature at minimum output
°C
58
64
59
Victrix X 24 2 I
Gas nozzle diameter (8205 gas valve)
mm
5.80
4.10
4.10
Gas nozzle diameter (848 gas valve)
mm
5.60
4.00
4.00
Flue flow rate at nominal heat output
kg/h
42
38
43
Flue flow rate at min heat output
kg/h
5
5
5
CO
2
at Nom Q./Min.
%
9.50 / 8.90
12.30 / 11.60
10.60 / 10.20
CO with 0% O
2
at Nom Q /Min.
ppm
200 / 4
650 / 4
190 / 3
NO
X
with 0% O
2
at Nom Q /Min.
mg/kWh
47 / 15
170 / 30
45 / 18
Flue temperature at nominal output
°C
57
63
57
Flue temperature at minimum output
°C
58
64
59