40
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
3.23 COMBUSTION PARAMETERS.
G20
G31
Supply pressure
mbar (mm H
2
O)
20 (204)
37 (377)
Victrix Maior 28 TT 1 ErP
Gas nozzle diameter
mm
6.15
6.15
Flue flow rate at nominal heat output
kg/h
46
47
Flue flow rate at min heat output
kg/h
5
5
CO
2
at
Q
. Nom./Min.
%
9.55 / 9.10
±
0,2
10.55 / 10.10
±
0,3
CO with 0% O
2
at Nom./Min.
Q
. Nom./Min.
ppm
135 / 10
223 / 13
NO
X
at 0% of O
2
at
Q
. Nom./Min.
mg/kWh
41 / 19
39 / 25
Flue temperature at nominal output
°C
51
52
Flue temperature at minimum output
°C
45
45
Victrix Maior 35 TT 1 ErP
Gas nozzle diameter
mm
6.15
6.15
Flue flow rate at nominal heat output
kg/h
55
56
Flue flow rate at min heat output
kg/h
6
6
CO
2
at
Q
. Nom./Min.
%
9.50 / 9.00
±
0,2
10.50 / 10.00
±
0,3
CO with 0% O
2
at Nom./Min.
Q
. Nom./Min.
ppm
134 / 5
143 /5
NO
X
at 0% of O
2
at
Q
. Nom./Min.
mg/kWh
34 / 21
30 / 24
Flue temperature at nominal output
°C
56
56
Flue temperature at minimum output
°C
47
47
Combustion parameters: measuring conditions
of useful efficiency (flow temperature/return
temperature= 80/60 °C), ambient temperature
reference = 15°C.