The Kit includes:
N° 1 - Gasket (1)
N° 1 - Concentric female flange (2)
N° 1 - Ring (3)
N° 1 - Aluminium tile (4)
N° 1 - Int./exhaust concentric pipe Ø
60/100 (5)
N° 1 - Fixed half-shell (6)
N° 1 - Mobile half-shell (7)
The adaptor kit includes:
N° 1 - Gasket (1)
N° 1 - Adaptor Ø 80/125 (2)
The Kit Ø 80/125 includes:
N° 1 - Ring (3)
N° 1 - Aluminium tile (4)
N° 1 - Fixed half-shell (5)
N° 1 - Mobile half-shell (6)
N° 1 - Int./exhaust concentric
pipe Ø 80/125 (7)
The remaining kit components
must not be used
1.12 CONCENTRIC VERTICAL KIT
INSTALLATION.
Type C configuration, sealed chamber and
fan assisted.
Concentric vertical intake and exhaust kit. This
vertical terminal is connected directly to the
outside of the building for air intake and flue
exhaust.
N.B.:
the vertical kit with aluminium tile
enables installation on terraces and roofs with
a maximum slope of 45% (approx 25°) and the
height between the terminal cap and half-shell
(374 mm for Ø 60/100 and 260 mm for Ø80/125)
must always be observed.
Vertical kit with aluminium tile Ø 60/100.
Kit assembly (Fig. 1-15): install the concentric
flange (2) on the central hole of the boiler,
positioning the gasket (1)
(which does not
require lubrication)
with the circular projections
downwards in contact with the boiler flange and
tighten using the screws contained in the kit.
Installation of the fake aluminium tile: replace
the tiles with the aluminium sheet (4), shaping
it to ensure that rainwater runs off. Position the
fixed half-shell (6) and insert the intake-exhaust
pipe (5). Fit the Ø 60/100 (3) concentric terminal
pipe with the male end (5) (smooth) into the
flange (2) up to the stop; making sure that the
wall sealing plate has been fitted (3), this will
ensure sealing and joining of the elements
making up the kit.
• Extensions for vertical kit Ø 60/100 (Fig. 1-16).
The kit with this configuration can be extended
to
a max. straight vertical length of 14.4 m
,
including the terminal. This configuration
corresponds to a resistance factor of 100. In
this case specific extensions must be requested.
Vertical kit with aluminium tile Ø 80/125.
Kit assembly (Fig. 1-17): to install the kit Ø
80/125 one must use the flanged adapter kit in
order to install the flue system Ø 80/125. Install
the flanged adaptor (2) on the central hole of the
boiler, positioning the gasket (1)
(which does not
require lubrication)
with the circular projections
downwards, in contact with the boiler flange and
tighten using the screws contained in the kit.
Installation of the fake aluminium tile: replace
the tiles with the aluminium sheet (4), shaping
it to ensure that rainwater runs off. Position the
fixed half-shell (5) on the aluminium tile and
insert the intake-exhaust pipe (7). Fit the Ø
80/125 concentric terminal pipe with the male
end (smooth) to the female end of the adapter
(1) (with lip gaskets) up to the stop; making sure
that the wall sealing plate (3) has been fitted, this
will ensure sealing and joining of the elements
making up the kit.
• Extensions for vertical kit Ø 80/125 (Fig.
1-18). The kit with this configuration can be
extended up to a
max. length of 32 m
including
the terminal. If additional components are
assembled, the length equivalent to the
maximum allowed must be subtracted. In this
case specific extensions must be requested.