MAGIS PRO ERP

Mono-phase hydronic module to 

pair with an outdoor condensing 

unit

Instruction and

 

recommendation booklet

IE

*1.039356ENG*

Summary of Contents for MAGIS PRO ERP

Page 1: ...MAGIS PRO ERP Mono phase hydronic module to pair with an outdoor condensing unit Instruction and recommendation booklet IE 1 039356ENG...

Page 2: ......

Page 3: ...be designed by qualified professionals within the dimensional limits established by the Law Installation and maintenance must be performed in compliance with the regulations in force according to the...

Page 4: ...l 14 2 4 System use 15 2 5 Troubleshooting 16 2 6 Parameters and information menu 18 2 7 Switching off the hydronic module 19 2 8 Restoring central heating system pressure 19 2 9 System draining 19 2...

Page 5: ...l spare parts Do not attempt to modify or repair the appliance alone Failuretocomplywiththeaboveimpliespersonal responsibility and invalidates the warranty Installation regulations this hydronic modul...

Page 6: ...this liquid must be followed scrupulously regarding the percentage necessary with respect to the minimum temperature at which the system must be kept An aqueous solution must be made with potential po...

Page 7: ...not to void the product war ranty before making unit connections carefully clean the heating system pipes radiators etc with special pickling or de scaling products to remove any deposits that could j...

Page 8: ...tionscompart ment Fig 1 5 To carry out electrical connections all you have to do is open the connections compartment as follows Remove the front panel Fig 3 5b Remove the cover b fig 1 4 1 Loosen the...

Page 9: ...s Comando Amico Remoto Remote Control V2 or On Off chrono thermostat electrical con nections Optional The operations described below must be performed after having removed the voltage from the applian...

Page 10: ...in central heating mode with external probe Zone 2 mixed flow temperature in cooling mode with external probe Key Rxx Heat regulation menu parameter TE Outdoor temperature TM Flow temperature U01 Zon...

Page 11: ...t the dehumidifier line has a minimum of 3 l kW dehumidifier hydraulic circuit connection 1 12 OPERATING LIMITS The system was designed to work in a specific range of temperatures and at a specific ma...

Page 12: ...motor shaft using a screwdriver Take great care during this operation to avoid damage to the motor Total head available to the system Head kPa A B Head available with by pass closed B Head available w...

Page 13: ...t Should it be necessary you can install an electrical resistance to supplement the central heating system this resistance can be installed directly inside the hydronic module 2 zone kit 1 direct and...

Page 14: ...light etc the appliance power cable must not be re placed by the user in the event of damage to the cable switch off the appliance and contact exclusively qualified staff for replacement if the applia...

Page 15: ...be considered as the hydronic module mount panel Attention if the hydronic module is switched off the CARV2 will display the connection error symbol ERR CM The CARV2 is still powered constantly so as...

Page 16: ...power to the hydronic module then power it back on If the Remote Control is still not detected at restart the system will switch to local operating mode i e using the controls on the control panel In...

Page 17: ...ing unit and its instructions booklet 1 E183 Condensing unit in test mode A signal notifies that the condensing unit is in test mode During this time room heating air condi tioning and domestic hot wa...

Page 18: ...humidity 0 99 D 42 Zone 2 relative humidity 0 99 D 43 Zone 1 humidistat OFF ON D 44 Zone 2 humidistat OFF ON D 45 Dehumidifier zone 1 OFF ON D 46 Dehumidifier zone 2 OFF ON D 47 Zone 1 circulator pump...

Page 19: ...the electric power supply completely empty the central heating circuit and the hydronic module domestic hot water circuit In systems that are drained frequently filling must be carried out with suitab...

Page 20: ...l adjustment devices check the production of domestic hot water check sealing efficiency of water circuits Even if just one single safety check provides a negative result do not commission the system...

Page 21: ...d M1 2 System circulator pump M10 1 Zone 1 circulator optional M10 2 Zone 2 circulator optional M31 2 Zone 2 mixing valve optional M52 Hot cold three way optional T1 Transformer Colour code key BK Bla...

Page 22: ...8 Storage tank function unabling resistance R14 Configuration resistance S20 1 Zone 1 room thermostat optional S20 2 Zone 2 room thermostat optional S36 1 Zone 1 humidistat optional S36 2 Zone 2 humid...

Page 23: ...in tap 4 Open the cap 1 and clean the filter 2 3 4 TROUBLESHOOTING N B maintenance interventions must be carried out by an authorised company e g Immergas After Sales Technical Assistance Service Nois...

Page 24: ...until the Password menu appears Enter the password modify the numer ical values using the DHW regulation buttons 5 and confirm with the OK button 1 Once you have accessed programming you can scroll th...

Page 25: ...nditioning For special systems e g zone systems with motorised valves etc it may be necessary to delay ignition 0 240 seconds step 10 sec 0 T 08 Display lighting Establishes the display lighting mode...

Page 26: ...ines the maximum flow temperature in room central heating mode in the low temperature zone 35 55 35 R 09 Low temperature zone minimum central heating Defines the minimum flow temperature in room centr...

Page 27: ...stem The function lasts for 18 hours and can be interrupted by pressing the ESC button and setting the function to OFF Activation of the function is signalled by the countdown shown on the indicator 1...

Page 28: ...function is activated in two different ways each time the hydronic module is re powered by pressing the buttons at the same time 3 and 5 Fig 2 1 for 5 seconds with the hydronic module in stand by N B...

Page 29: ...two screws a 2 Press the hooks inwards which block the lower grid b 3 remove the grid b Front panel Fig 3 5b 4 Open the protection door e1 pulling it towards you 5 Remove the cover caps c and loosen...

Page 30: ...e control panel i 10 Tilt the control panel i towards you The control panel i can rotate until the support cord j is completely extended 11 If the left side needs to be removed unhook the support cord...

Page 31: ...changer water inlet remains at 23 C 18 C outdoor air temperature 35 C Performance in compliance with EN 14511 Central heating mode status heat exchanger water inlet remains at 40 C 45 C outdoor air te...

Page 32: ...154 201 Nominal heat output kW 7 80 5 50 6 00 Average temperature 47 55 Parameter Value Colder zones Average zones Hotter zones Annual energy con sumption for the central heating function QHE kWh year...

Page 33: ...ure operating limit Pdh 4 2 kW Tj temperature operating limit COPd 2 03 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv...

Page 34: ...ture operating limit Pdh 5 5 kW Tj temperature operating limit COPd 2 36 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv...

Page 35: ...operating limit Pdh 4 6 kW Tj temperature operating limit COPd 3 31 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv 4 C...

Page 36: ...ture operating limit Pdh 4 6 kW Tj temperature operating limit COPd 1 73 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv...

Page 37: ...ature operating limit Pdh 4 3 kW Tj temperature operating limit COPd 1 49 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbi...

Page 38: ...operating limit Pdh 4 2 kW Tj temperature operating limit COPd 2 09 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv 7 C...

Page 39: ...5 10 5 70 5 50 Average temperature 47 55 Parameter Value Colder zones Average zones Hotter zones Annual energy con sumption for the central heating function QHE kWh year 11475 5469 2882 Room central...

Page 40: ...re operating limit Pdh 5 5 kW Tj temperature operating limit COPd 1 93 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv 2...

Page 41: ...ture operating limit Pdh 5 9 kW Tj temperature operating limit COPd 1 97 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv...

Page 42: ...operating limit Pdh 6 5 kW Tj temperature operating limit COPd 3 20 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv 1 C...

Page 43: ...ure operating limit Pdh 6 0 kW Tj temperature operating limit COPd 1 75 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv...

Page 44: ...ature operating limit Pdh 4 0 kW Tj temperature operating limit COPd 0 98 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbi...

Page 45: ...operating limit Pdh 4 9 kW Tj temperature operating limit COPd 1 54 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv 4 C...

Page 46: ...W 9 00 10 00 8 80 Average temperature 47 55 Parameter Value Colder zones Average zones Hotter zones Annual energy con sumption for the heating function QHE kWh year 13274 7214 3765 Room central heatin...

Page 47: ...ure operating limit Pdh 6 6 kW Tj temperature operating limit COPd 1 93 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv...

Page 48: ...rature operating limit Pdh 8 1 kW Tj temperature operating limit COPd 2 59 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tb...

Page 49: ...e operating limit Pdh 8 4 kW Tj temperature operating limit COPd 3 01 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv 7...

Page 50: ...ature operating limit Pdh 6 9 kW Tj temperature operating limit COPd 1 75 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbi...

Page 51: ...rature operating limit Pdh 4 5 kW Tj temperature operating limit COPd 0 98 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tb...

Page 52: ...e operating limit Pdh 6 6 kW Tj temperature operating limit COPd 1 54 for air water heat pumps Tj 15 C if TOL 20 C Pdh kW for air water heat pumps Tj 15 C if TOL 20 C COPd Bivalent temperature Tbiv 4...

Page 53: ...pplementary boiler From boiler board Room central heating seasonal energy efficiency in colder and hotter climate conditions The energy efficiency of the set of products indicated in this sheet may no...

Page 54: ...11 2013 in case of an assembly including a boiler to integrate with the heat pump In this case the heat pump must be considered as the main appliance of the assembly Fig 3 9 Parameter Magis Pro 5 ErP...

Page 55: ...e of the products compared to the size and features of the building Room central heating seasonal energy efficiency of the assemble in av erage climate conditions Room central heating seasonal energy...

Page 56: ...d 1 039356ENG rev ST 002317 000 01 16 Inglese per IRLANDA IE Followus Immergas Italia immergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 12...