A
B
C
D
E
F
G
A
++
A
+
A
B
C
D
E
F
G
MAGIS COMBO 5
A
++
A
+
62
dB
dB
kW
kW
7,70
7,80
7,10
6,10
6,20
6,00
55 °C
35 °C
48
3.30 PRODUCT FICHE (IN COMPLIANCE WITH REGULATION 811/2013).
Low temperature (30/35)
Parameter
Value
Colder zones
Average
zones
Hotter zones
Annual energy con-
sumption for the heating
function (Q
HE
)
kWh/year
5513
3190
1566
Room central heating
seasonal efficiency (η
s
)
ηs %
137
155
203
Nominal heat output
kW
7.80
6.10
6.00
Average temperature (47/55)
Parameter
Value
Colder zones
Average
zones
Hotter zones
Annual energy con-
sumption for the heating
function (Q
HE
)
kWh/year
6937
4988
2416
Room central heating
seasonal efficiency (η
s
)
ηs %
106
115
134
Nominal heat output
kW
7.70
7.10
6.20
For proper installation of the appliance refer to chapter 1 of this booklet (for the installer)
and current installation regulations. For proper maintenance refer to chapter 3 of this booklet
(for the maintenance technician) and adhere to the frequencies and methods set out herein.