INSTALLING THE DEVICE

1.1  DESCRIPTION OF THE DEVICE.

The abbreviation “D.I.M.” (Disgiuntore Idrico Multi-impianti - 

multi-system distribution manifold) identifies a series of kits that 

Immergas has designed for the management of central heating 

systems with large water capacities. In particular, they are kits that 

can only be coupled with some boiler models in the Immergas 

range, including an open manifold (distribution manifold) and 

a circulator.

IMPORTANT:

 the boiler models set-up for coupling with the mani-

folds are Immergas boilers with P.C.B. designed for the management 

of zone systems.

These kits are characterised by the possibility to be recessed in the 

wall, therefore have no clearance.

The zone served by the distribution manifold is managed by an 

Immergas chrono-thermostat connected to the boiler.

1.2  INSTALLATION RECOMMENDATIONS.

The place of installation of the appliance and relative Immergas 

accessories must have suitable features (technical and structural) 

such to allow (always in safety, efficiency and comfortable con-

ditions):

- installation (according to the provisions of the technical legis-

lation and technical regulations);

- maintenance operations (including scheduled, periodic, routine 

and special maintenance);

- removal (to outdoors in the place for loading and transporting 

the appliances and components) as well as their eventual replace-

ment with appliances and/or equivalent components.

Only professionally qualified companies are authorised to install 

the Immergas Multi-System Distribution Manifold. Installation 

must be carried out according to regulation standards, current 

legislation and in compliance with local technical regulations and 

the required technical procedures. Before installing the device, 

ensure that it is delivered in perfect condition; if in doubt, contact 

the supplier immediately. Packing materials (staples, nails, plastic 

bags, polystyrene foam, etc.) constitute a hazard and must be kept 

out of the reach of children. In the event of malfunctions, faults or 

incorrect operation, turn the device off immediately and contact 

an authorised company (e.g. the Authorised Technical Assistance 

centre, which has specifically trained staff and original spare 

parts). Do not attempt to modify or repair the appliance alone. 

Failure to comply with the above implies personal responsibility 

and invalidates the warranty.

Recess installation.

Do the masonry work creating an opening in the wall suitable to 

contain the device (See parag. “Main dimensions”).

Insert the distribution manifold (1) in its seat, remembering to 

open the four support fins (2) before inserting it (Fig. 1).

Protect the side edges and the front cover during the recess prepa-

ration for the device.

IMPORTANT:

 the hydraulic and electrical connections must 

be made within the device unit; you must therefore position the 

frame first and then perform the connections.

Attention: 

the recessed frame is not a supporting structure and 

cannot replace the piece of wall removed. It is therefore necessary 

to check the correct positioning inside the wall.

Wall-hanging installation.

Fasten the frame to the wall using four expansion plugs suitable 

for the type of wall and weight of the device (not supplied) and 

using the four drilled holes (see Fig. 2 pos. X).
Use the fairlead and the sheath-holder (3) supplied to limit the 

infiltration of water inside the frame.

Summary of Contents for ERP DIM BASE

Page 1: ...ERP MULTI SYSTEM DISTRIBUTION MANIFOLD ERP DIM BASE IE Instructionsandrecommendations Installer User Maintenancetechnician 1 039169ENG...

Page 2: ......

Page 3: ...sions of the regulations in force and the principles of good practice In compliance with legislation in force the systems must be designed by qualified professionals within the dimensional limits esta...

Page 4: ...e 11 1 11 Kits available on request 11 2 Use and maintenance instructions 12 2 1 General warnings 12 2 2 Warnings for the user 12 2 3 Cleaning the case 12 3 Checks and maintenance 13 3 1 Wiring diagra...

Page 5: ...must be carried out according to regulation standards current legislation and in compliance with local technical regulations and the required technical procedures Before installing the device ensure...

Page 6: ...MENSIONS Height mm Width mm Depth mm 700 450 190 Key RG Generator return G 3 4 MG Generator flow G 3 4 V Electrical connection X Holes for DIM wall mounted fastening ErP DIM Base A System return G 3 4...

Page 7: ...uit 1 5 ELECTRICAL CONNECTION The appliance has an IPX5D protection degree electrical safety of the appliance is reached only when it is connected properly to an efficient earthing system as specified...

Page 8: ...ey must be connected electrically directly to the boiler see instructions in boiler manual Attention it is also necessary to install the relay board in the boiler as shown in Fig 3 1 configuring relay...

Page 9: ...G Do not use G Y Y Y G Do not use G Y Y Y G Constant curve speed 1 G Y Y Y G Constant curve speed 2 G Y Y Y G Constant curve speed 3 Constant curve the pump operates maintaining constant speed The pu...

Page 10: ...able to the system Key Vn Available head An Circulating pump absorbed power Circulator pump absorbed power W Circulator pump absorbed power W Circulator pump absorbed power W Flow rate l h Flow rate l...

Page 11: ...the system via the boiler filling valve Filling is performed at low speed to ensure release of air bubbles in the water via the boiler and central heating system vents and of the distribution manifold...

Page 12: ...fore prohibited to open the device front lid The only operation that the user must perform is to periodically check the water pressure of the system in the boiler The boiler pressure gauge should read...

Page 13: ...n the electric and hydraulic con nections If even only a single safety check offers a negative result do not commission the system 3 1 WIRING DIAGRAM BOILER CONNECTION USING ERP DIM BASE 3 RELAY BOARD...

Page 14: ...ndo Amico Remoto V2 remote control and the internal 1 relay board In this case the electrical connection of the CARV2 must be made directly to the boiler as described in the relative instruction book...

Page 15: ...RELAY If a remote control or zone control room thermostat is used its electric connection must be made directly to the boiler as de scribed in the relative instruction book Key M10 1 DIM zone 1 pump...

Page 16: ...Neutral 4 Line 5 Multi service board 6 Low voltage connection terminals BK Black BL Blue BR Brown 3 5 TROUBLESHOOTING Presence of air in the system Check the opening of the boiler vents of the the cen...

Page 17: ...9 Total head available in direct zone with 1000 l h flow rate max kPa m c a 42 90 4 37 Empty device weight kg 12 5 Full device weight kg 13 9 Electrical connection V Hz 230 50 Maximum input A 0 60 Ins...