1.6 INSTALLATION LAYOUTS.
If you are using a Comando Amico Remoto
V2
(C.A.R.
V2
) or Super
C.A.R. zone control remote control, it must be connected directly
to the boiler (see instructions in boiler manual).
The C.A.R.
V2
or Super C.A.R. remote control will control the zone,
pre-defined as main on the manifold.
The C.A.R.
V2
or Super C.A.R. remote control must be set with
on-off operation (see the relative instruction manual).
In this case, the T.A. electric connections of the zone, defined as
the main zone of the manifold, must be left free.
N.B.:
combined with the Victrix Superior range boiler (new version
2021), the jumper on the RT connections of zone 1 (managed remo-
tely) must be maintained (or used for contacts of zone shutter valves).
N.B.:
combined with boilers other than Victrix Superior (new ver-
sion 2021), the jumper on the RT connections of the zone defined
as main
must be eliminated
.
Installation layout of 2 homogeneous zones.
Key:
S20-1 - Direct zone 1 room thermostat (RT)
S20-2 - Direct zone 2 room thermostat (RT)
1 - External probe (optional)
2 - Boiler
3 - Comando Amico Remoto
V2
or Super C.A.R. remote control
(optional)
RZ1 - Direct zone 1 return
RZ2 - Direct zone 2 return
MZ2 - Direct zone 2 flow
MZ1 - Direct zone 1 flow
Factory settings define zone 1 as the main zone.
(See Fig. 14 for electrical connection and Fig. 15 for zones control unit
setting)