3.17 ZONE MANAGEMENT P.C.B.
The zone control unit can be configured using the selector switches
on the unit (2 Fig. 38), via which you can choose between the
following options:
n°
OFF
ON
S25
1 Homogeneous zone
control
Mixed zone control
2 N° 1 mixed zone (Z2)
N° 2 mixed zones (Z2 and
Z3)
3 Master board
Slave board
S26
4 Main zone = zone 1
Main zone = zone 2
5 Super CAR: main zone
flow control
Super CAR: system flow
control
6 Mixed zones max. temper-
ature = 50°C
Mixed zones max. temper-
ature = 75°C
S27
7 Normal functioning
Not used
8 Not used
Not used
9 Mixed zones minimum
temperature = 25°C
Mixed zones minimum
temperature = 35°C
S28
10 Not used
Not used
11 Not used
Not used
12 Not used
Not used
- S26 (5) can only be modified if the Super C.A.R. remote control
can be coupled with the Superior kW range boilers.
- S26 (6) in the event of the setting with max. flow temperature of
75°C, the relative safety thermostat must be replaced with one
suitable for supporting this temperature.
Warnings.
Various LEDs are present on the board to display the
functioning status and to indicate any anomalies.
The LEDs from 1 to 7 (1 Fig. 38) identify the activation of the
relative relay:
- LED H1 zone 1 activation (high temperature)
- LED H2 zone 2 activation (low temperature)
- LED H3 zone 3 activation (optional)
- LED H4 mixed zone 2 mixer opening
- LED H5 mixed zone 2 mixer closure
- LED H6 mixer opening zone 3 (optional)
- LED H7 mixer closing zone 3 (optional)
The LED H11 signals that the zone management board is powered.
LEDs 8 and 9 indicate the functioning status of the board:
Warning
H8
H9
H10
CH request presence
ON
OFF
OFF
Disabling of active zones
ON L
OFF
OFF
Zone 2 safety thermostat interven-
tion
OFF
ON
OFF
Mixed zone 2 probe fault
OFF
ON L
OFF
Zone 3 safety thermostat interven-
tion
OFF
OFF
ON
Mixed zone 3 probe fault
OFF
OFF
ON L
DIM BUS Anomaly
OFF ON A ON A
DIM ERP communication present
OFF
OFF
ON F
DIM ERP mixed zone safety ther-
mostat intervention
OFF ON V OFF
Key:
ON = ON
OFF = OFF
ON L = Slow flashing (0.6 s on, 0.6 s off)
ON V = Fast flashing (0.3 s on, 0.3 s off)
ON F = Flash flashing (0.2 s on, 1 s off)
ON A = Alternate flashing
Zone management P.C.B.
Key:
1 - Relay functioning signal LED (
H1 ÷ H7
)
2 - Zone management board functioning mode
selectors
3 - Board functioning status signal LED (
H10
)
4 - Board functioning status signal LED (
H9
)
5 - Board functioning status signal LED (
H8
)
6 - Board power supply signal (
H11
)
7 - Mixed zone 3 flow temperature adjustment
trimmer
8 - Mixed zone 2 flow temperature adjustment
trimmer