MI07A592-Rev1011-GB  

 

1/4

 

FIRE/503 WATER-N 

ELECTRONIC CONTROLLER FOR 

FIREPLACES 

 

INTRODUCTION 

We thank you for your trust and congratulate you for choosing 
one of our products. This device is a BUILT-IN ELECTRONIC 
CONTROLLER FOR FIREPLACES that manages four devices 
through microprocessor logic: two circulators, one diverter 
valve and one auxiliary output.  
 

COMPLIANCE WITH STANDARDS:

 

 

EN 60730-1 as subsequently amended  

 

EN 60730-2-7 

 

EN 60730-2-9 

COMPLIANCE WITH DIRECTIVES: 

 

B.T. 73/23/EEC 

 

E.M.C. 89/336/EEC 

as subsequently amended CE 93/68/EEC

 

 

TECHNICAL CHARACTERISTICS  

POWER SUPPLY = 230Va.c./50Hz (+10%-15%)  

TEMPERATURE  PROBE = NTC 1%  

MAXIMUM PROBE TEMPERATURE = 150°C  

OPERATING TEMPERATURE = 0÷50°C 
STORAGE TEMPERATURE = 0÷60°C  
OPERATING HUMIDITY = 10%÷90% with no condensate 
ADJUSTMENT = with relays  (I max. = 3A)  
ABSORBED POWER = 1VA 
LCD DISPLAY  

TEMPERATURE DISPLAY = 5÷85°C (1°C resolution)  

DEGREE OF PROTECTION = IP20 (installed product)  

INSTALLATION CONDITIONS = normal environment 

ASSEMBLY  = in standard 3–module flush-mounted box DIN503 

NON-VOLATILE DATA STORAGE ON FLASH TECHNOLOGY  

KEYPAD = in rubber with 8 keys 
BUZZER internal for alarm signalling 

 

CONTROLS LEGEND 

 

 

+ / - keys 

Increases or decreases the selected value 

 

SET key

 

Enables the SET Point function  

E key

   

Enables the Enter function 

A key 

 

Enables the Automatic function 

T button

 

Press T to store the new parameters  

OFF key

 

Press OFF to turn off the controller 

DIMENSION 

 

 
 
 
 
 
 

INSTALLATION AND CONNECTIONS 

 
SAFETY INSTRUCTIONS 

 

Before you connect the controller to the mains, make 

sure that voltage is CUT OUT and that it corresponds 
to a value of 230Va.c. 

(Fig. 3). 

 

 

 

 

 

 

 

The fireplace must be connected to the mains, with a 

line 

differential main switch

, in compliance with regulations 

in force. 

Make sure that the electrical characteristics of the motor to be 
controlled are compatible with those of the product 

(Imax=3A). 

The manufacturer is not liable for improper use of the device. 

 

POSITIONING 

 

Do not install in places where temperature can exceed 
40°C 

(Fig.4)

 

 

 

 

 

 

Make sure the box is expressly intended to contain the 
product only, and that it is NOT used as a shunt 

(Fig.5)

 

 

 
 
 
 
 
 

INSTALLATION 

A)

 

Connect the wires to the terminal boards as shown in the 

electrical diagram (see paragraph “electrical wirings” and 
“application diagram” below) 

B)

 

Fit the controller inside the 3-module box previously 

mounted within the wall, and secure everything using the 
screws supplied with the product  

 
 
 
 

Fig. 3 

Fig. 4 

Fig. 6 

Fig. 1 

 

 

Fig. 5 

Fig. 2 