E211101X_rev02_ENG
29/06/2022
15
-
Referring to any opening a closing device, change the gasket, if necessary, after the opening: check damages
on the gasket contact surface.
-
The installer must provide suitable tools to avoid risks caused by the air intake and exhaust obstructions.
-
Each connection must be fixed using suitable locking elements and controller yearly.
-
At the working shift beginning the pressure must increase gradually, the steam must be open slowly (see the
relative paragraph)
-
During long time of rest, the roller external surface must be protected against rust with suitable substances
The roller programmed life is 10 years: after this time, the machine must be qualified again.
Dangers may be caused by:
-
Steam looses because of the couples breaking down: these leaks are contained inside the machine. Following
eventual steam looses, all the machine supply must be cut, and the correct maintenance must be done.
-
At the end of the roller life, the couples may cause steam looses. This loose can happen near the machine sides.
In this case, stop the machine and verify if the roller must be changed.
14.
COMPRESSED AIR CONNECTION (only for ironer equipped with folding system)
Compressed air connection must be performed by qualified technician and in compliance with national and local rules
and standards. Compressed air supplying the circuit must have the following specification:
-
minimum pressure: 6 bar
-
air blew default pressure: 2.9 bar
-
air connection: 12mm rapid connection.
-
Condenses outlet: 6mm rapid connection.
-
Minimum capacity: 500 litre/h (in case of on compressor dedicated to the machine, we suggest a minimum
tank of 50 litres)
All connection between installation system and equipment must be proofed. We suggest you use a spray identifying
leaks; otherwise, you can spread some foamy not corroding substances. In any case no bubbles must form. In case there
are some leaks, please repair them.
At the end, close the side panels, start the machine and using the two gauges on the back control the correct air pressure.