1
www.imerusa.com | IMER USA (301) 336-3700
Koine 35 Quick User Guide
IMER USA
Page 1: ...1 www imerusa com IMER USA 301 336 3700 Koine 35 Quick User Guide IMER USA...
Page 2: ...the material to be used The Koine 35 is a continuous pump mixer that can only be used with pre blended materials It is not suitable for use with bulk sand and cement It should not be used after the pr...
Page 3: ...ntrol 6 Water booster pump switch 7 Water pressure indicator 8 Mixing chamber safety sensor 9 Forward Reverse 10 Rotor stator speed control Fig 1 Step 2 Attach the water supply line to the bottom port...
Page 4: ...ifferent nozzles and pick the one that is best for your appli cation Note Air compressor and spray wand are used only for spraying appli cations such as fireproofing plastering or stucco The air compr...
Page 5: ...ure If that is the case you must switch on the booster pump 6 shown in Fig 7 Note Water pressure must be more than 40 PSI for the green light 7 to be on Using the water booster is recommended to keep...
Page 6: ...er feeding wheel Fig 9 The feeding wheel will not start spin ning until 9 forward Fig 7 is turned on Note Water pressure must be more than 40 PSI for the green light 7 to be on Switching on the water...
Page 7: ...n the material coming out is the consistency that you like that is your water setting Note A good starting point for the water column is at 600 LPH 159 gal lons per hour for most materials such as fir...
Page 8: ...coats the inside of the hose to fill in the pores and slick the line This priming method is used for every type of cement pump Note This process can be skipped if using a product with high cement con...
Page 9: ...en close the air valve on spray wand if spraying or switch off the forward reverse switch 9 in Fig 7 if you are just pumping You can resume again by opening air valve in spray wand or switching the sw...
Page 10: ...om the cam lock end and attach it to the supplied 25mm to geka coupler adapter Then connect this hose onto the the water supply geka fitting Fig 13 Collect the sponge ball from the other end Fig 14 No...
Page 11: ...e the motor hatch gently and make sure to align the motor coupler with the shaft Switch on the pump in which the clean out tool will scrape the sides as it lowers down the mixing chamber You should no...
Page 12: ...olts of current and 30 amps slow down your pumping speed ERR 05 The water pump and the compressor have been turned on for more than 15 minutes and during this period they have not been used Or the com...