SubVIS Orca II - User Manual
IMENCO AS
Visiting Address:
Kophaug 3, 5570 Aksdal, Norway
Office: +47 52 86 41 00
Org No: 923 005 749 MVA
Mail Address:
PO. Box 2143, 5504 Haugesund, Norway
Fax:
+47 52 86 41 01
www.imenco.com
17
4.4.2
Subsea connector type and pin-out
Figure 7, Orca II camera - standard connector and RJ45 plug with T568B colors
The Orca II camera standard subsea connector is SubConn®
D DLSAM
The wires from this connector internally in the camera are color coded and connected to terminals of
the camera electronics as indicated in Table 4. The Ethernet twisted pairs are terminated according
to T568B as shown with an image of a RJ45 plug in Figure 7 and color names in Table 4.
Orca II camera
Internal electronics
SubConn® DBCR-13-M:
Terminal Description
Number
Internal Wire color
Conductor
Power in
Minus
J12 PWR
−
Black
1
DC Power
Not connected
Orange (screen)
2
Power in
Plus
J12 PWR
+
White
3
BI-DA + / Tr
RJ45-1
White/Orange
9
Twisted
pairs
T568B
color
scheme
BI-DA - / Transmit -
RJ45-2
Orange
8
BI-DB + / R
RJ45-3
White/Green
11
BI-DC +
RJ45-4
Blue
6
BI-DC -
RJ45-5
White/Blue
7
BI-DB - / Receive -
RJ45-6
Green
10
BI-DD +
RJ45-7
White/Brown
5
BI-DD -
RJ45-8
Brown
4
RS232 TxD *
J13-2
Red
12
Optional
use
RS232 GND *
J13-6
Green
13
Table 4, Orca II camera standard subsea connector pinout (Ethernet connected as T568B)
The Orca II camera is powered by an adequate DC source
(24 V
, minimum 20W
)
connected with
polarity and pin numbers as indicated in Table 4.
*) The galvanic isolated RS232 output is optional and could be replaced with RS485 or GPIO(0-5V).