background image

 

 

 

IE-MiniMc LFPT and Telco/LFPT  

Operation Manual 

 
 
 
 
 

 
 
 
 
 

 
 
 

 

Summary of Contents for IE-MiniMc LFPT

Page 1: ...IE MiniMc LFPT and Telco LFPT Operation Manual...

Page 2: ...riques de classe B prescrites dans le R glement sur le brouillage radio lectrique publi par le minist re des Communications du Canada Class B using any DC jack options This equipment has been tested...

Page 3: ...End user agrees to accept all liability for loss of or damages to the returned product during shipment IMC Networks shall repair or replace the returned product at its option and return the repaired...

Page 4: ...ounting Options 1 Powering the IE MiniMc LFPT and Telco LFPT 2 About Power Over Ethernet PoE and IE MiniMc LFPT and Telco LFPT 2 LED Operation 2 Link Fault Pass Through LFPT 3 DC Terminal Block Wiring...

Page 5: ...y anywhere as a standalone device in locations with extremely limited space Installation options include Velcro strips DIN rail mounting with DIN Rail clips A wall mount bracket A PowerTray 18 for hig...

Page 6: ...urcing Equipment PSE Power Sourcing Equipment distributes an electrical current across existing copper data cabling When powering an IE MiniMc Telco LFPT and using 48 VDC power the copper port s Ether...

Page 7: ...force all LINK LEDs off DC Terminal Block Wiring Instructions The IE MiniMc LFPT and Telco LFPT can also be powered with the DC terminal block From a power source connect to any one positive and any o...

Page 8: ...near the upper limit of the device s specification for example 50 volts take precautions to limit the voltage at the units terminal block When turning on high voltage DC circuits initial voltages may...

Page 9: ...tible 48 VDC allows for an absolute maximum voltage of 56 5 VDC AC Wall Adapter 100 to 240 10 VAC input 5 VDC output 2A max Operating Temperature 40 F to 185 F 40 C to 85 C DC configuration 14 F to 12...

Page 10: ...tween blasting with clean dry compressed air and flushing with methanol to remove particles of dirt Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to any product add...

Page 11: ...ars this symbol on product or packaging must not be disposed of with unsorted municipal waste This symbol indicates that the equipment should be disposed of separately from regular household waste It...

Page 12: ...mation in this document is subject to change without notice IMC Networks assumes no responsibility for any errors that may appear in this document IE MiniMc LFPT and Telco LFPT is a trademark of IMC N...