background image

 
 

 

 
 
 

 
 
 
 
 

 

 
 
 
 
 
 

Hardware Manual 

 

VisionBox DAYTONA

 

 
 

 
 

Version 1.0 

 May 2019

 

Summary of Contents for VisionBox DAYTONA

Page 1: ...Hardware Manual VisionBox DAYTONA Version 1 0 May 2019...

Page 2: ...________________________________11 4 1 Power Connector 11 4 2 System LEDs 11 5 Interfaces _____________________________________________________12 5 1 Ethernet 12 5 1 1 Power over Ethernet ____________...

Page 3: ...re opening the housing make sure that the VisionBox is disconnected from power Use appropriate ESD protection when changing components Please take special note of the voltage range which may be applie...

Page 4: ...d the GigE Action Command This allows transferring data power and trigger signal using a single Ethernet cable The integrated Real Time Communication Controller RTCC ensures proper timing for trigger...

Page 5: ...Contains functional units for controlling I Os in real time Trigger unit creation of trigger signals derived from other inputs e g en coder I O Scheduler applies values stored in a FIFO to outputs in...

Page 6: ...owing table shows available features and interfaces for the VisionBox DAYTONA Jetson TX2 Main Storage 32 GB eMMC SD card slot Ethernet 3 1000 Mbit s USB 2 USB 3 0 1x micro USB service port Dig I Os 8...

Page 7: ...2 Introduction Page 7 22 IMAGO Technologies GmbH Strassheimer Str 45 61169 Friedberg Germany Tel 49 6031 6842611 info imago technologies com www imago technologies com 2 3 Block Diagram...

Page 8: ...fluenced by the actual hardware configuration the system workload and the mounting situation The temperature range should be veri fied for each application Note The heat sink can transfer more heat in...

Page 9: ...rameter Min Typ Max Unit Input Voltage 24 30 V High Level Current Threshold 1 5 mA Maximum Current Internal Limited 6 21 mA Threshold Voltage 6 11 V Signal Frequency 5 MHz Digital Output Parameter Min...

Page 10: ...l Data Page 10 22 IMAGO Technologies GmbH Strassheimer Str 45 61169 Friedberg Germany Tel 49 6031 6842611 info imago technologies com www imago technologies com 3 2 Dimensions Figure 1 Housing dimensi...

Page 11: ...on While the signal is pulled to GND the VisionBox is held in reset state Leaving the signal floating is the default mode for normal operation Mating external plug component Phoenix Contact MC 1 5 4 S...

Page 12: ...e GigE Vision Action Command on Ethernet ports 1 and 2 It can be used to trigger cameras over Ethernet in real time The GigE specification allows sending these messages by a different device distinct...

Page 13: ...ted by a green blinking ON LED Only use this mode if advised by IMAGO Do not try to flash the Jetson OS image provided by NVIDIA If a PC is connected after the VisionBox has already booted the followi...

Page 14: ...r VGA monitor an active adapter is needed Figure 7 DP connector 5 5 SD Card The SD card socket supports SDHC and SDXC memory cards with a maximum interface speed of 104 MB s UHS I Figure 8 SD card soc...

Page 15: ...ent Limit Current Limit IN 0 IN 1 IN 7 Real Time Communication Controller FPGA VisionBox Figure 11 Simplified digital I O circuit The input group requires an external connection of a shared GND refere...

Page 16: ...tal Outputs Power Supply OUT 0 VCC Power VCC GND Trigger IN Camera OUT 1 OUT 7 Figure 13 Digital output example 1 Depending on the voltage and isolation requirements of the application the VisionBox c...

Page 17: ...A Figure 15 D Sub 15 HD connector For example the AMPHENOL connector L77HDE15SOL2 can be used to make a connection to the VisionBox Pins 5 and 15 provide a 5 V 12 V power supply for RS 422 encoders Th...

Page 18: ...imago technologies com 6 Internal Connectors The removable cover allows access to the following internal components M 2 socket for SATA SSD M 2 socket for LTE 4G modem Nano SIM socket Before removing...

Page 19: ...rmany Tel 49 6031 6842611 info imago technologies com www imago technologies com 6 1 M 2 SSD The M 2 connector with type M keying notches can be used for adding an SSD to the VisionBox It supports 80...

Page 20: ...gies com www imago technologies com 6 2 M 2 LTE Modem The M 2 connector with type B keying notches allows the use of 4G LTE modems with a USB 2 0 interface A module length of 42 mm is supported Figure...

Page 21: ...imago technologies com 7 Support Finally if you have any open questions the IMAGO support team is happy to assist you in any way For direct contact to the support please use our ticket system https i...

Page 22: ...IMAGO Technologies GmbH Strassheimer Str 45 61169 Friedberg Germany Tel 49 6031 6842611 info imago technologies com www imago technologies com 8 History Revision Date Changes Initials 1 0 May 2019 Fi...

Reviews: