background image

 

 
 
 
 

K

-

60

 

instruction manual

 

 
 

 

Summary of Contents for K-60

Page 1: ...K 60 instruction manual...

Page 2: ...board 6 2 11 Chinese Settings 6 2 12 Transmission speed selection 7 2 13 Multinational keyboard 8 2 14 Output forced letter case conversion 9 3 Reading mode 10 3 1 Trigger mode 10 3 2 Continuous mode...

Page 3: ...lor codes 23 6 2 2 1D code reverse color setting 23 6 2 3 QR code reverse color setting 23 6 3 Code 128 24 6 3 1 Restore default settings 24 6 3 2 Enable Disable Code 128 24 6 3 3 Set length limit 24...

Page 4: ...tore Default Setting 33 6 11 2 Enable Disable Industrial 25 33 6 11 3 Set length Limit 33 6 11 4 Check and output check 34 6 12 IATA 2 of 5 34 6 12 1 Restore default setting 34 6 12 2 Enable Disable I...

Page 5: ...ength limit 40 6 17 MSI Plessey 41 6 17 1 Restore Default Setting 41 6 17 2 Enable Disable MSI Plessey 41 6 17 3 Set length limit 41 6 18 PDF 417 42 6 19 QR Code 42 6 20 Micro QR 42 6 21 Data Matrix 4...

Page 6: ...1 1 Product introduction 1 1 Factory Default Terminator Enter r Factory Default 1 2 Obtain device information product version number...

Page 7: ...is 15200bps bluetooth setting TTL RS232 Wireless Setting 115200bps Bluetooth Setting 2 2 4g communication was used when R B4 0 wireless scanning gun was connected with the supporting u disk receiver...

Page 8: ...er scanning the pairing code open the bluetooth device for bluetooth search and connection The pairing code I disconnect The pairing code II connect 2 2 Show and hide keyboard for apple devices only S...

Page 9: ...tocktaking mode Upload all data Upload new data Show saved data Show upload data Clear all the data 2 4 Singlechip restore factory setup 2 5 Set upload data delay valid when connecting to cell phone N...

Page 10: ...nner sofeware version Query the receiving end version number 2 7 Set the sleep time X 1yyy xxx1000 is non dormant sleep time formula yyy 10 z seconds non dormant 60 seconds 120 seconds 5 minutes 10 mi...

Page 11: ...reading mode can be configured as a standard keyboard by scanning the USB KBW setting code USB KBW keyboard 2 10 USB COM keyboard When the reading mode is connected to the host using the USB cable th...

Page 12: ...7 2 12 Transmission speed selection Don t delay Delay 5 ms Delay 10 ms Delay 15 ms Delay 20 ms Delay 25 ms Delay 30 ms Delay 35 ms Delay 40 ms Delay 45 ms...

Page 13: ...some of the input characters vary from country to country and different languages are required The keyboard defaults to USA English USA Belgium Finland France Germany Italy Sweden UK Denmark Norway S...

Page 14: ...utput a bar code with letter content you can configure the output to be all uppercase or lowercase For example if the bar code is ab123de if converted to uppercase bar code output result is AB123DE if...

Page 15: ...cation interface To start a new trigger reading the host needs to cancel the trigger level first and then send the trigger level trigger mode 3 2 Continuous mode Continuous mode refers to the working...

Page 16: ...ssful output of information or single reading time out the reader will be some time interval can be set to re enter the monitoring state In the autosensing mode the reader can also start reading the c...

Page 17: ...circumstances Normal No lighting Always 4 2 Aiming There is a projection device on the reading module which is used to project a special figure when shooting the reading module and it represents the c...

Page 18: ...e 5 2 All beeps In various scenarios the reading module has the boot prompt sound the successful reading prompt sound and the setting code prompt sound This setting code can control all the prompts So...

Page 19: ...ID prefix suffix end character etc will be allowed to be added to the data output content Prohibit adding all information The start character Code ID prefix suffix end character etc will not be added...

Page 20: ...Modify prefix Read the modify prefix content setting code and combine the read data code to modify the prefix content Use 2 hexadecimal values for each prefix character and the prefix allows up to 16...

Page 21: ...lt value please use it with caution The default CODE ID for all bar codes 5 6 2 Modify the CODE ID The Code ID of each bar code type can be modified independently and it needs to be used by reading th...

Page 22: ...UPCE1 Code ID Modify UPCA Code ID Modify IATA25 Code ID Modify Code 39 Code ID Modify Code 93 Code ID Modify Interleaved 2 of 5 Code ID Modify Codabar Code ID Modify Industrial 25 Code ID Modify Matri...

Page 23: ...customized and modified by the user after decoding the information Allow to add a suffix no allow to add a suffix 5 7 2 Modify the suffix Read the modify suffix content setting code and combine the re...

Page 24: ...5 8 1 Add terminator Choose to read the following setting codes you can make the reading module add the end character or no longer add the end character Add terminator No add terminator 5 8 2 Modify t...

Page 25: ...inator to add the carriage return CR Add carriage return and line feed CRLF Add LF Add tab stops TAB Add terminator ETX 5 9 Data segment editing 5 9 1 Data segment interception The decoding informatio...

Page 26: ...esponding setting code and use it in combination with the data code The length can be modified from 0 255 Modify the length of the Start segment to 0x02 example 1 The hexadecimal system of 0x02 is rep...

Page 27: ...all one dimensional bar code symbol types Read the following setting codes and only perform unified operations on all one dimensional bar code symbol types or all allow reading or all prohibit reading...

Page 28: ...bit read the reverse color code 6 2 2 1D code reverse color setting Allows to read 1D reverse color code Probit reading 1D Reverse color code 6 2 3 QR code reverse color setting Enable PDF417 reverse...

Page 29: ...fault settings Code 128 Defaulted 6 3 2 Enable Disable Code 128 Enable Code 128 Disable Code 128 6 3 3 Set length limit Set minimum length limit 00 Set minimum length limit 04 Set maximum length limit...

Page 30: ...fter setting to Read 2 digit extension code or Read 5 digit extension code the reader module can read barcode symbols with extension codes or barcode symbols without extension codes After setting to D...

Page 31: ...code or Read 5 digit extension code the reader module can read barcode symbols with extension codes or barcode symbols without extension codes After setting to Do not read 2 digit extension code or D...

Page 32: ...ble EAN13 to ISSN 6 5 6 EAN13 to ISSN Other configurations are the same as EAN13 Disable EAN13 to ISSN Enable EAN13 to ISSN 6 6 UPCE0 6 6 1 Restore default settings UPCE0 Defaulted 6 6 2 Enable Disabl...

Page 33: ...system characters 6 7 UPCE1 6 7 1 Restore default settings UPCE1 Defaulted 6 7 1 Enable Disable UPCE1 Enable UPCE1 Disable UPCE1 6 7 2 Output verification Output check No Output check 6 7 3 Output sy...

Page 34: ...g to Do not read 2 digit extension code or Do not read 5 digit extension code the extension code attached to the bar code symbol will not be read and output Disable 2 digit extension code Enable 2 dig...

Page 35: ...can read barcode symbols with extension codes or barcode symbols without extension codes After setting to Do not read 2 digit extension code or Do not read 5 digit extension code the extension code at...

Page 36: ...re verification and users can choose to use verification according to different applications Set to No Verification the reading module will not verify the barcode data Set to USS verification but not...

Page 37: ...t settings Restore Matrix 25 default settings 6 10 2 Enable Disable Matrix 25 Enable Matrix 25 Disable Matrix 25 6 10 3 Set length limit Set minimum length limit 00 Set minimum length limit 04 Set max...

Page 38: ...ck 6 11 Industrial 2 of 5 6 11 1 Restore Default Setting Industrial 25 Defaulted 6 11 2 Enable Disable Industrial 25 Enable Industrial 25 Disable Industrial 25 6 11 3 Set length Limit Set minimum leng...

Page 39: ...the maximum length 6 11 4 Check and output check No check out Check but not output check Check but not output check 6 12 IATA 2 of 5 6 12 1 Restore default setting IATA 25 Defaulted 6 12 2 Enable Dis...

Page 40: ...limit04 Set maximum length limit32 Set minimum length limit255 Customized the minimum length Customized the maximum length 6 12 4 Check and output check No check Check but not output check Check and o...

Page 41: ...nding character Enable starting character and Ending character Disable starting character and Ending character 6 13 4 Enable Disable Set Length Limit Set minimum length limit00 Set minimum length limi...

Page 42: ...le Code32 Enable Code32 6 13 7 Full ASCII Support The encoding method of Code 39 can include the representation of all ASCII characters By setting the reading module can support bar codes containing t...

Page 43: ...Limit Set minimum length limit00 Set minimum length limit04 Set maximum length limit32 Set maximum length limit255 Customized minimum length Customized maximum length 6 14 4 Set whether to output veri...

Page 44: ...C and D The terminator is represented by T N and E It can be set to not output the start character and stop character or output one of four formats Disable start character and stop character Enable st...

Page 45: ...et maximum length limit32 255 Customized minimum length Customized maximum length 6 16 Code 11 6 16 1 Restore Default Setting Code 11 Defaulted 6 16 2 Enable Disable Code 11 Enable Code 11 Disable Cod...

Page 46: ...d maximum length 6 17 MSI Plessey 6 17 1 Restore Default Setting MSI Plessey Defaulted 6 17 2 Enable Disable MSI Plessey Enable MSI Plessey Disable MSI Plessey 6 17 3 Set length limit Set minimum leng...

Page 47: ...mum length Customized maximum length 6 18 PDF 417 Enable PDF 417 Disable PDF 417 6 19 QR Code Enable QR Disable QR 6 20 Micro QR Enable Micro QR Disable Micro QR 6 21 Data Matrix Enable Data Matrix Di...

Page 48: ...43 6 22 Micro PDF417 Enable MicroPDF417 Disable MicroPDF417 6 23 Aztec Enable Aztec Disable Aztec...

Page 49: ...de 7 1 Data code 0 F Data code 0 Data code 1 Data code 2 Data code 3 Data code 4 Data code 5 Data code 6 Data code 7 Data code 8 Data code 9 Data code A Data code B Data code C Data code D Data code E...

Page 50: ...ong data For example if a setting code is read and the data 1 2 and 3 are successively read the last read digit 3 will be cancelled if Cancel the last read bit of data if Cancel the previous read stri...

Page 51: ...ous mode Trigger mode Single reading time 3000ms Setting range 1000 3600000ms Trigger condition Level Same reading delay No Delay Rereading timeout reset No Same reading delay time 1500ms Induction mo...

Page 52: ...rder The prefix comes before the Code ID Prefix adding Not Prefix content No CodeID No Suffix adding No Suffix content No Ending character adding YES Ending character content 0x0D Data segment interce...

Page 53: ...ut system character Output 2 bit extension code Disable 5 bit extension code Disable UPCA Reading Enable UPCA to EAN13 Disable Output check character Output 2 bit extension code Disable 5 bit extensio...

Page 54: ...nd ending character NO Full ASCII support NO Convert to Code 32 NO Max length 255 Min length 0 Codabar Reading Enable Check No Output check character NO Output starting character and ending character...

Page 55: ...50 PDF417 Reading Enable QR Reading Enable Micro QR Reading No Data Matrix Reading Enable Micro PDF417 Reading No Parameter name Default settings Remark Aztec Reading No Inverse color code NO...

Page 56: ...N 13 d UPC E0 c UPC E1 c UPCA c Interleaved 2 of 5 e Matrix 2 of 5 v Industrial 2 of 5 D IATA25 s Code 39 b Codabar a Code 93 i PDF417 r QR Q Data Matrix u Code 11 H MSI Plessey J Micro QR Q Code32 b...

Page 57: ...R CarriageReturn 0e 14 SO ShiftOut 0f 15 SI ShiftIn 10 16 DLE DataLinkEscape 11 17 DC1 XON DeviceControl1 12 18 DC2 DeviceControl2 13 19 DC3 XOFF DeviceControl3 14 20 DC4 DeviceControl4 15 21 NAK Nega...

Page 58: ...2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 ForwardSlash 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3a 58 Colon 3b 59 Semi colon 3c 60 LessThan 3d 61...

Page 59: ...8 X 59 89 Y 5a 90 Z 5b 91 Left OpeningBracket 5c 92 BackSlash 5d 93 Right ClosingBracket 5e 94 Caret Circum ex 5f 95 _ Underscore 60 96 GraveAccent 61 97 a 62 98 b 63 99 c 64 100 d 65 101 e 66 102 f 6...

Page 60: ...55 Hexadecimal Decimal Character 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122 z 7b 123 Left OpeningBrace 7c 124 VerticalBar 7d 125 Right ClosingBrace 7e 126 Tilde 7f 127 DEL Delete...

Reviews: