Jam Sync Mode
To set the output timecode to a specific time, set
Data > Advanced Status and Control >
Timecode > Output > Jam Sync Time
to the desired time and then set the corresponding
jam sync input time source
(Output 1/Output 2/LTC Time Source)
to
Copy jam sync
time to all output time
.
To enable all output timecode manually and immediately, set
Immediate Jam Sync
to
Yes
.
You can also set up the Selenio X100 to jam sync the output time to the input time daily at
a specific time. To do this, set
Data > Advanced Status and Control > Timecode >
Output > Jam Sync Time
to the desired time and select an input time source using the
c
orresponding jam sync input time source (Output 1/Output 2/LTC Time Source).
The
following input time sources are supported:
LTC
VITC 1
VITC 2
ATC 1
ATC 2
Note:
Since RP196 timecode is embedded in the HANC space (as well as ATC timecode if it
has been enabled for embedding in HANC), enabling ADS clean in
Audio > Embedding >
Embedding x > Control
will remove all packets in the entire HANC space of the
corresponding processing channel. When in proc bypass mode, this will strip out all HANC
timecode packets. The X100 is not affected by this limitation when it is in conversion mode,
since timecode packets are re-embedded to the video after the conversion.
If HANC timecode is to be preserved in proc bypass mode, set the
Emb x ADS Clean
control to
No
, and the
Emb x Group x Embedding Mode
to
OverWrite
. This will
produce the same result as if
ADS Clean
is enabled.
Audio Embedding
Handling of Non-PCM/Compressed Audio Signals
The Selenio X100 automatically detects input non-PCM audio signals, such as compressed
Dolby E audio, even without the proper C/V bits set (the C/V bits are corrected in this
situation). Detected non-PCM audio inputs then automatically bypass the sample rate
converter and are embedded in the output SDI stream unprocessed.
You can also manually bypass sample rate conversion using the SRC control parameters
located at
Audio > Sync and Delay.
Summary of Contents for Selenio X100
Page 8: ...Selenio X100 Installation and Operation Manual viii...
Page 21: ...Selenio X100 Installation and Operation Manual 9 Figure 1 5 X100 Signal Flow...
Page 22: ...Selenio X100 Installation and Operation Manual 10...
Page 38: ...Selenio X100 Installation 26...
Page 158: ...Appendix A Laser Safety Guidelines 146...
Page 178: ...166...