Creating a
Custom
Aspect Ratio
You can scale and pan the output image to any size and location by using the module’s
custom aspect ratio feature. You can use the ARC Scaling and ARC Offset controls to adjust
the size and position of your custom ARC settings. Custom ARCs can then be saved as ARC
Presets. You can save up to five ARC Presets.
Descriptions of the controls are listed below.
ARC H Scale
–sets the horizontal size of the output image anywhere between minimum
and 200% of the output screen size.
ARC V Scale
–sets the vertical size of the output image anywhere between minimum
and 200% of the output screen size.
ARC H Offset
–places the horizontal center of the output image anywhere between
-50% and 50% of the output screen size.
ARC V Offset
–places the vertical center of the output image anywhere between -50%
to 50% of the output screen size.
lists the minimum ARC scaling values for each HD-SDI output video standard.
To create and save a custom ARC preset, follow these steps
1
To set the horizontal and vertical scaling and offset values for your custom ARC, make the
following selections:
2
To save the current custom ARC settings as an ARC preset, make the following selection:
3
Wait approximately two seconds for the module to process the command.
When the save operation is complete, the
ARC Preset Save
parameter option returns
to
None
.
You can at any time select your new ARC Preset for output. For more information see
Selecting a Standard ARC Preset
Table 3-4
Minimum ARC Scaling Values
Scaling Controls
HD-SDI Output Video Standard/Frame Rate
Parameter Name
720p/50 Hz
720p/59.94 Hz
1080i/50 Hz
1080i/59.94 Hz
Vertical Scale
40–200%
33.75–200%
53.34–200%
45–200%
Horizontal Scale
56.25–200%
56.25–200%
37.50–200%
37.50–200%
Setting Description
Parameter Navigation
Select the Custom ARC option.
Video Setup
Processing
ARC Preset Select
[
1
,
4
]
Custom
Set the ARC horizontal scaling
value.
ARC H Scale [
1
,
7
]
Minimum–200.00%
(see
Set the ARC horizontal offset.
ARC V Scale [
1
,
8
]
-50.00% to 50.00%
Set the ARC vertical scaling value.
ARC H Offset [
1
,
9
]
Minimum–200.00%
(see
Set the ARC vertical offset.
ARC V Offset [
1
,
A
]
-50.00% to 50.00%
Setting Description
Parameter Navigation
Save the current ARC as a preset.
Video Setup
Processing
ARC Preset Save
[
1
,
C
]
(Select Preset 1–5)
Summary of Contents for Selenio 6800 HUC6801+D
Page 3: ...Edition A August 2010 HUC6801 D Broadcast Upconverter Installation and Operation Manual...
Page 4: ......
Page 8: ...Contents vi Copyright 2010 Harris Corporation...
Page 18: ...Chapter 1 Introduction 6 Copyright 2010 Harris Corporation...
Page 56: ...Chapter 5 Specifications 44 Copyright 2010 Harris Corporation...