Power Supply Electrical Specification
Table 123:
Power Supply Electrical Specifications
Item
Specification
Input Voltage
Universal AC Input (90VAC to 265VAC)
Input Frequency
47 - 63Hz
Power Factor
Correction
>96% Efficient, Active, Meets EN61000-3-2 as a Class A Device when under 50% Load, Max Test Voltage
230VAC
Inrush Current
Less than or equal to 50 Amps peak at 264VAC
Power Supply
Efficiency
Meets 80Plus Gold Efficiency Standard at Input Voltage of 230VAC. Greater Than 80% Over Input Voltage
Range
Output Voltages
V1 = 5VDC, V2 = 24VDC
Output Currents
5VDC @ 10Amps, 24VDC
Output Fusing
24VDC Outputs (Pins 3 and 26 of Power Connector) each to be Fused to Prevent Output Current from
Exceeding 40 Amps
Output Power
1500 Watts (Continuous)
Line Regulation
< +/- 0.1%
Load Regulation
+/- 2.0% for 24VDC Output, +6.0/-2.0% for 5VDC Output
Output Noise
100mV P-P (20Mhz Bandwidth, Measured across 0.1uF and 10 uF capacitors connected in parallel)
Overcurrent
Protection
Non-destructively limit current to 110% rated maximum output, Square Current Limit with Automatic
Recovery
Overvoltage
Protection
Entire power supply shuts down if any output rail reaches 15% above rated voltage
Current Sharing
Active, All Outputs, N+1 Hot Swappable (Diode Isolation), 20% Tolerance on Loads greater than 50%,
Current Shares with Present Power Supply Model
Holdup Time
16 milliseconds at One-Half Maximum Output Power
Indicators
LEDs indicating 5VDC, 24VDC, and Fan Fail present on front cover. LEDs indicate complete failure of
Voltage Rails, or Fan not operating, or deviation from specified voltages, or Fan speed not nominal
Alarms
Alarm PCB to monitor both voltage rails and Cooling Fan and make four status signals available at the Main
Connector for Remote Monitoring
I2C Communications Serial communications to provide all parameters listed in Table 2. Reference Table 1 for pin assignments.
R1500 to be configured as Slave device. If CLK or DATA lines are pulled to GND or VCC power supply
operation must not be affected
MTBF
> 250,000 Hours @ 30 Degrees Celsius (Excludes Fan Life)