Controllable Parameters
Table 101:
PT-AEBT-IB/PT-AECT-IB User-Controllable Parameters List
[RO] = Read-only parameter
Parameter
R/W
Description
Options
Module
Back Module Type
RO
Displays the back module type connected to the
PT-AEBT-IB
or
PT-AECT-IB
module
PT-AEBT-BMI
PT-AECT-BMI
PT-AEB-BMI
PT-AEC-BMI
Audio Reference
R/W
Selects AES reference input for source
Sync 1
Sync 2
Sync 3
Sync 4
Parameter Hysteresis
R/W
Sets hysteresis for parameters needing it
0 to 5 seconds in 500
ns steps
Sync Select
R/W
Selects which physical sync port the module uses
as a reference
Sync 1
Sync 2
Sync 3
Sync 4
In
Tone (1-16)
(Table Parameter)
R/W
Indicates type of tone to send out AES output
Pass Input
Silence
500 Hz
1 KHz
Polarity Reversal (1-32)
(Table Parameter)
R/W
Re and - to correct audio polarity in the
analog domain
Normal
Invert
SRC
R/W
Enables SRC, if licensed
No
Yes
Signal Presence (1-16) [RO]
(Table Parameter)
RO
Reports presence or absence of valid signal
No
Yes
Phase Alarm (1-16) [RO]
(Table Parameter)
RO
Alarm set if left and right channels are out of
phase
No
Yes
Clip Detect (1-32) [RO]
(Table Parameter)
RO
Reports if signal on the input exceeds the
maximum input amplitude
No
Yes
Bypass (1-16)
(Table Parameter)
RO
For signals routed to wideband xpt only - tells
control to make switch regardless of signal
presence
On
Off
Swap/Copy (1-16)
(Table Parameter)
R/W
Swap/Copy left and right audio channels
(NOTE: This parameter is always applied after
summing)
No Swap
Swap
Left To Right
Right To Left
Level Adjust (1-32)
(Table Parameter)
R/W
Indicates gain/attenuation applied to mono
channel
10 dB to -30 dB in 0.5