60
HUC6800
+
Installation and Operation Manual
Appendix A: Communication and Control Troubleshooting Tips
•
A legacy 6800 series product is in the frame.
+
Pilot Lite cannot
communicate with legacy 6800 series products. They will not be
discovered or controlled by
+
Pilot Lite, although they can be
installed in the FR6802
+
frame and work using card edge controls.
The module must be from the 6800
+
product family.
•
Check that the back module does not have any bent pins. Follow
this procedure:
a. Unplug the front module first
b. Unscrew and remove the back module.
c. View the 30-pin spring connector at the bottom of the back
Figure A-1.
Connector on 6800
+
Back Module
This connector should not have any bent or pressed pins. Even
a slightly depressed or bent pin may cause genlock issues.
d. If there are bent pins, carefully re-position them to their correct
positions.
If this is not possible, a back module can be obtained from the
manufacturer.
+
Pilot Lite Does Not Find All Modules in Frame
If a discovery is started too soon after frame power-up,
+
Pilot Lite will
not find all the installed modules. Refresh
+
Pilot Lite (
File
>
Refresh
), and ensure that installed modules are fully powered-up first
before discovery.
30-pin
connector
Summary of Contents for Selenio 6800 HUC6800
Page 4: ......
Page 8: ...vi HUC6800 Installation and Operation Manual Contents...
Page 22: ...8 HUC6800 Installation and Operation Manual Chapter 1 Introduction...
Page 36: ...22 HUC6800 Installation and Operation Manual Chapter 2 Installation...
Page 70: ...56 HUC6800 Installation and Operation Manual Chapter 4 Specifications...
Page 82: ...68 HUC6800 Installation and Operation Manual Index...
Page 83: ......