HUC6800
+
Installation and Operation Manual
13
Chapter 2: Installation
Local and Remote Jumper Settings
Follow this procedure to set the
REM/LOC
jumper for either remote or
local control:
1. Locate the
REM/LOC
control jumper on the module (beside the
mode select rotary switch).
shows the
standard location of the
REM/LOC
jumper.
2. Place a jumper on pins 1 and 2 to set the module for Remote
control, or pins 2 and 3 to set the module for Local control. See
Figure 2-2. REM/LOC
Settings for Remote and Local Control
See
for more information on local/remote control
jumper functionality.
Genlock Termination Jumper Settings
Follow this procedure to set the Genlock Termination jumper J1:
1. Locate jumper
J1
on the module, near the back of the module.
(
shows the location of the jumper.)
2. Place a jumper on pins 1 and 2 to set the module for No
Termination, or pins 2 and 3 to set 75
Ω
Onboard Termination
Figure 2-3.
Genlock Termination Settings
Note
You must configure modules for
local or remote operation
prior
to power-up. To change the
configuration, first remove
power from the module, reset
the jumper, and then reapply
power.
The white triangle near the
jumper pins on the module
indicates pin 1.
1 2 3
1 2 3
Remote control
Local control
1 2 3
1 2 3
No Termination
75
Ω
Termination
Summary of Contents for Selenio 6800 HUC6800
Page 4: ......
Page 8: ...vi HUC6800 Installation and Operation Manual Contents...
Page 22: ...8 HUC6800 Installation and Operation Manual Chapter 1 Introduction...
Page 36: ...22 HUC6800 Installation and Operation Manual Chapter 2 Installation...
Page 70: ...56 HUC6800 Installation and Operation Manual Chapter 4 Specifications...
Page 82: ...68 HUC6800 Installation and Operation Manual Index...
Page 83: ......