background image

Setup & Operator Manual        Compass Product Line

 

L610-0220  REV A 

 

 

www.imagediagnostics.com

 

                 

8

 

 

7.

 

Compass Accessories & Disposables

 

7.1.

 

 Item 7:  X610-0208 – Bag, Sterile, Compass Contour, 17”x 27” with contoured notch 

7.2.

 

 Item 7:  C610-0209 – Bag, Sterile, Compass Frame, 28”x 20” 

 

8.

 

Instructions for Operation & Usage

 

8.1.

 

Vendor OEM vertical articulation spring arms weight and connection data.

 

8.1.1.

 

Compass Contour and Frame weight varies from 10 – 11 kg/22 – 24 lbs. 

8.1.2.

 

Use only vendor OEM supplied vertical articulation spring arms having a spring force rating 
that supports a 10-11 kg load and will accept a Compass connection shaft diameter of 
between 28.5-29mm. 

8.2.

 

Emergency Patient Access 

 

 
 
 

8.2.1.

 

For emergency access to patient, manually rotate and move the shielding barrier away from 
patient area to a safe distance and location for emergency access. 

    

8.3.

 

Compass Product attachment to vertical spring arms will vary per OEM vendor.  See 
spring arm manufacturer’s installation & user manual for instructions. 

8.3.1.

 

On the vertical spring arm connection end, remove small metric screw from the collar or 
plug. Slide collar up (Ondal) or remove insert plug (OASYS) and remove key (Do not lose). 
Having key ready, move Compass shaft hub into vertical arm shaft hole, insert key, slide 
collar over (Ondal) or insert plug (OASYS), insert metric screw and tighten (See photos 
below). 

 

  

  

 

 

8.4.

 

Vertical arm adjustments for vertical limits

 

 

8.4.1.

 

Adjust vertical heights and spring force per OEM vendor adjustment manual instructions. 
Height and Force adjustments are up to the user’s discretion.

 

 
 

 

WARNING!

 

In the event of an emergency where direct accessed to 

patient is needed, do these steps quickly to move 

Compass Radiation Shield Barrier away from patient.

 

Key 

Summary of Contents for Compass Product Line

Page 1: ...he picture shown Setup Operator Manual The text of this manual was originally written approved and published by the manufacturer in English The information and images in this document are proprietary...

Page 2: ...c assumes no liability or responsibility for after sale operating or safety practices nor can it be responsible for personal injury or damage resulting from misuse Never make modifications or adjustme...

Page 3: ...s 6 4 EMC Electromagnetic Compatibility Statement 7 5 Compass Product Main Assemblies versions may vary 7 6 Compass Product Components 7 7 Compass Accessories Disposables 8 8 Instructions for Operatio...

Page 4: ...anual for reference Warning Information or instructions shown near this symbol must be adhered to in order to prevent a potentially hazardous situation which if not avoided could result in death perso...

Page 5: ...persons using this equipment must fully understand its operation instructions emergency procedures capabilities be aware of all potential safety hazards This manual should be accessible to all person...

Page 6: ...result in minor or moderate injury or equipment damage WARNING Do not modify this equipment CAUTION It is the user s responsibility to make sure the equipment is safe and operates properly prior to u...

Page 7: ...1 Item 1 Yoke Shaft inserts into vertical spring arm attached by means of a shaft arm key and collar to lock key in place Arrows show full rotation in both directions 7 2 Item 2 Window Side Supports...

Page 8: ...r away from patient area to a safe distance and location for emergency access 8 3 Compass Product attachment to vertical spring arms will vary per OEM vendor See spring arm manufacturer s installation...

Page 9: ...ex or other glass cleaners even if they are environmentally friendly organic or non scented Should anything ever stick to an acrylic surface such as an adhesive label or gummy substance do not use any...

Page 10: ...ng c Always use a new clean cloth to wash Never use a cloth used for another cleaning job for this could scratch the acrylic Approved cleaner listed above d Do not use paper towels scrub pads or other...

Page 11: ...12 01 99 Should be disposed of in registered landfill sites in accordance with Local Authority regulations COMPONENT ITEM RECYCLING GROUP Frame Brackets Support and clamping components Metal Steel and...

Page 12: ...0 50mm All Compass products have horizontal rotation of 360 degrees All Compass products have vertical rotation of 350 degrees Only vendor OEM vertical spring arms with spring ratings between 9 15 Kg...

Page 13: ...tion Qty Label 1 L610 0218 LABEL SERIAL NUMBER COMPASS 1 2 L000 0004 LABEL UDI BARCODE 1 3 L610 0224 LABEL COMPASS MANUAL QR RATING 1 Date Code of Manufactured Compass Products in the format of Year M...

Page 14: ...ine L610 0220 REV A www imagediagnostics com 14 15 Warranty Warranty details for IDI Products can be obtained directly from Image Diagnostics Inc Image Diagnostics Inc 310 Authority Drive Fitchburg MA...

Reviews: