Technical Specifications
Power Consumption
Max. 70W during operation
Power Requirements
100-240V AC, 1.3A, 50-60Hz
Earth connection necessary
Interface to Computer
SCSI-2 (ANSI X3.131)
Front Panel
Power on/off/cancel button
Drawer out/cancel button
Status indicator LED's
Noise Generation
£
60 dB @ 1m when focusing
£
60 dB @ 1m when scanning
Drum Force
< 1kg (2.2lbs)
Operating Environment
Temperature: 10
°
C-35
°
C (50
°
F-95
°
F)
Humidity: 20%-80%RH (no condensation).
Storage Environment
Temperature: 0
°
C-50
°
C (32
°
F-122
°
F)
Relative humidity: 20%-80%RH (no condensation)
Drum scanner Formats
Transparencies: from 35mm to 4x5 inches,
£
1mm thick
Flatbed Formats
¥ Electrostatic holder for one or more reßectives with total area up
to 314 x 460 mm (A3),
£
1mm thick
¥ Glass plates for multiple transparencies with total area up to
314 x 460 mm (A3),
£
10 mm thick
¥ Glass plates for one or more reßectives with total area up to
314 x 460 mm (A3),
£
10 mm thick
Lamp types
Drum: Osram FM 6w/860
Light table: Osram FM 8w/860
Flatbed reßective: Osram FM 11w/860
Flatbed transmission: Osram FM 11w/860
Summary of Contents for Flextight Progression
Page 1: ...Italiano Fran ais Espa ol Deutsch English Flextight Progression by imacon...
Page 2: ...English Deutsch Espa ol Fran ais Italiano...
Page 3: ...English User s Guide Imacon Flextight Progression...
Page 47: ...Deutsch Anwenderhandbuch Imacon Flextight Progression...
Page 93: ...Espa ol Manual de instrucciones Imacon Flextight Progression...
Page 137: ...Fran ais Manuel de l utili sateur Imacon Flextight Progression...
Page 181: ...Italiano Manuale Utenti Imacon Flextight Progression...