background image

Fig. 8B

Fig. 8A

USER CHARACTERISTICS

GAS BURNERS

Before Leaving

Check all connections for gas leaks with soap and water. DO NOT use a naked flame for detecting leaks.  Ignite all burners 

both individually and concurrently to ensure correct operation of gas valves, burners and ignition. Turn gas taps to low 

flame position and observe stability of the flame for each burner individually and concurrently.  When satisfied with the 

hotplate, please instruct the user on the correct method of operation. In case the appliance fails to operate correctly after all 

checks have been carried out, refer to the authorised service provider in your area.

TYPE PRESSURE mbar

NORM.

BURNER

Ø INJECTORS

1/100

NOMINAL GAS

 CONSUMPTION

Natural gas

1.00 kPa

fast

155

11.7

semifast

117

6.9

auxiliary

92

4.1

Wok 

(single control)

180

14.4

Wok Dual

130 (outer)

17.5 (outer & inner)

80 (inner)

Universal

LPG

2.75 kPa

fast

94

11.9

semifast

70

6.5

auxiliary

56

4.1

Wok 

(single control)

108

14.4

Wok Dual

70 (outer)

48 (inner)

 

MJ/h

3.2 (inner)

16.0 (outer & inner)

2.9 (inner)

Summary of Contents for ILBV604

Page 1: ...INSTRUCTION MANUAL GAS COOKTOPS IL 604 IL 775 IL 905 BV WV and SS models ...

Page 2: ...OPEN 24 7 ILVE ACCESSORIES ONLINE SHOP VY H PKL YHUNL VM JVɈLL THJOPULZ WVKZ HUK V OLY 03 HJJLZZVYPLZ H OL JSPJR VM H I VU ZOVW PS L JVT H ...

Page 3: ...OWLEDGE UNLESS THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE BY A PERSON RESPONSIBLE FOR THEIR SAFETY CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE Dear customer We thank you and congratulate you on your choice This new carefully designed product manufactured with the highest quality materials has been carefully tested to satisfy...

Page 4: ...he burner is ignited as in the various cases described above keeping the knob fully pressed on the maximum position for approximately 3 5 seconds After releasing the knob make sure the burner is actually lit N B We recommend the use of pots and pans with a diameter matching that of the burner thus preventing the flame from escaping from the bottom part and surrounding the pot do not leave any empt...

Page 5: ...y clogged the electrical parts are cleaned with a damp cloth and are lightly greased with lubricating oil when still warm the stainless steel grids of the working area after having been heated take on a bluish tint which does not deteriorate the quality To bring colour back to its original state use as lightly abrasive product N B Cleaning of the taps must be carried out by qualified personnel who...

Page 6: ...510 909 490 840 53 5 55 510 620 480 560 770 55 490 510 750 Fig 2 mod ILBV604 mod ILBV775 ILWV775 mod ILSS775 510 909 55 490 840 770 55 490 510 750 ...

Page 7: ...09 55 490 840 770 55 490 510 750 510 909 55 490 840 770 55 490 510 750 asbestosmat betweenpanandpan supportasseriousdamagetothe appliancemayresult Donotremovethepansupportand enclosetheburnerwithawokstandas ontothehotplate Donotuselargepotsorheavyweights ...

Page 8: ...Fig 5 There are two ways to carry out the connection to the main gas line A The hotplate can be connected with rigid pipe as specified in AS NZS5601 B The hotplate can be connected with a Flexible Hose which complies with AS NZS 1869 Australian Certified 10mm ID class B or D no more than 1 2m long and in accordance with AS NZS 5601 Ensure that the Hose does not contact the hot surfaces of the hotp...

Page 9: ...nd law provisions in force The earth connectionis compulsory in terms of the law Should there be no cable and or plug on the equipment use suitable absorption material for the working temperature as well as indicated on the matrix plate Under no circumstance must the cable reach a temperature above 50 C of the ambient temperature If connecting directly to the mains power supply fit a multi pole sw...

Page 10: ... as follows replacetheinjector Fig 7 withthecorresponding type of gas to be used see table User characteristics to adjust to the minimum use a screwdriver on the screw placed on the tap Fig 8 after turning the tap to its minimum position For GPL butane propane screw tight A B Fig 7 Fig 8 solo Wok solo MiniWok Solo Wok Dual ...

Page 11: ...isfied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to operate correctly after all checks have been carried out refer to the authorised service provider in your area TYPE PRESSURE mbar NORM BURNER Ø INJECTORS 1 100 NOMINAL GAS CONSUMPTION Natural gas 1 00 kPa fast 155 11 7 semifast 117 6 9 auxiliary 92 4 1 Wok single control 180 14 4 Wok...

Page 12: ...SLWOVUL 5 TILY 03 ZOV YVVTZ HYL VWLU KHPS MYVT HT WT HUK H YKH Z HT WT I HWWVPU TLU VUS VU H YKH Z PS L JVT H 5 LHK 6ɉJL 4VVYL YLL 3LPJOOHYK 0 VVYHR 9VHK HTILY LSS 83 H LUKPZO 9VHK VVYWHYVV 5 UP V L YLL 6ZIVYUL 7HYR 5L ALHSHUK 76 V_ VJRI YU OYPZ JO YJO ...

Reviews: