Fig. 8B
Fig. 8A
USER CHARACTERISTICS
GAS BURNERS
Before Leaving
Check all connections for gas leaks with soap and water. DO NOT use a naked flame for detecting leaks. Ignite all burners
both individually and concurrently to ensure correct operation of gas valves, burners and ignition. Turn gas taps to low
flame position and observe stability of the flame for each burner individually and concurrently. When satisfied with the
hotplate, please instruct the user on the correct method of operation. In case the appliance fails to operate correctly after all
checks have been carried out, refer to the authorised service provider in your area.
TYPE PRESSURE mbar
NORM.
BURNER
Ø INJECTORS
1/100
NOMINAL GAS
CONSUMPTION
Natural gas
1.00 kPa
fast
155
11.7
semifast
117
6.9
auxiliary
92
4.1
Wok
(single control)
180
14.4
Wok Dual
130 (outer)
17.5 (outer & inner)
80 (inner)
Universal
LPG
2.75 kPa
fast
94
11.9
semifast
70
6.5
auxiliary
56
4.1
Wok
(single control)
108
14.4
Wok Dual
70 (outer)
48 (inner)
MJ/h
3.2 (inner)
16.0 (outer & inner)
2.9 (inner)