1
2
3
6
7
4
5
CRC-121
DIGITAL CABLE
RECEIVER
V/A LOOP
8
QAM IN
CONTROL
SYNC
STATUS
+12V
RF OUT
IKUSUP
+12V
5A
QAM IN
SYNC
STATUS
+12V
RF OUT
CONTROL
QAM IN
SYNC
STATUS
+12V
RF OUT
CONTROL
QAM IN
SYNC
STATUS
+12V
RF OUT
CONTROL
QAM IN
SYNC
STATUS
+12V
RF OUT
CONTROL
QAM IN
SYNC
STATUS
+12V
RF OUT
CONTROL
CRC-01
1
DIGITAL
CABL
E
RECEIVER
CRC-01
1
DIGITAL
CABL
E
RECEIVER
CRC-01
1
DIGITAL
CABL
E
RECEIVER
CRC-01
1
DIGITAL CABLE
RECEIVER
CRC-01
1
DIGITAL CABLE
RECEIVER
+12V
INPUT
OUTPUT
AUX INPUT
Gain 5 dB
GAIN
OUTPUT TEST
ON
INPUT TEST
HPA-120
BROADBAND
AMPLIFIER
47-862 MHz
Ref. 4426
CAM
CAM
CAM
CAM
CAM
POWER
CFP-500
POWER SUPPL
Y
Ref. 4429
+24V
60mA
QAM IN
OUT
ESTACION MODULAR PARA RECEPCION DVB-C MULTICRYPT
MODULAR HEADEND FOR MULTICRYPT DVB-C RECEPTION
STATION MODULAIRE POUR RÉCEPTION DVB-C MULTICRYPT
«CRC»
TV-Cable Digital
Digital Cable-TV
TV-Câble Numérique
— Estación «CRC» para 5 cadenas TV. Contiene 5 Receptores
CRC-011, 1 Amplificador HPA-120 y 1 Alimentador CFP-500.
— «CRC» headend for 5 TV stations. It contains 5 CRC-011
Receivers, 1 HPA-120 Amplifier and 1 CFP-500 Power Supply.
— Station «CRC» pour 5 chaînes TV. Contient 5 Récepteurs
CRC-011, 1 Amplificateur HPA-120 et 1 Alimentation CFP-500.
COMMON INTERFACE
COMMON INTERFACE
COMMON INTERFACE
COMMON INTERFACE
COMMON INTERFACE
Nivel de entrada (64QAM)
Input level (64QAM)
Niveau d'entrée (64QAM)
Ganancia paso lazo de entrada
Input loop-through gain
Gain de dérivation en entrée
Formatos modulac. entrada
Input Modulation Schemes
Modulations d'entrée
Nivel ajustable salida canal TV
Adjust. TV channel output level
Niveau réglable sortie canal TV
Atenuación paso lazo de salida
Output loop-through loss
Perte de multiplexage de sortie
Alimentación
Power requirements
Alimentation
Temperatura de funcionamiento
Operating temperature
Températures de fonctionnement
Frecuencia de entrada
Input frequency
Fréquence d'entrée
Régimen de entrada
Input symbol rate
Débit d'entrée
51 - 858 MHz
-64 ... -20 dBm
0.5
±1
dB
16, 32, 64,
128, 256QAM
65 - 80 dB
µµµµµ
V
1.1 dB
+12 V
DC
/ 700 mA*
0° ... +45° C
CARACTERISTICAS PRINCIPALES /
MAIN TECHNICAL DATA /
DONNÉES TECHNIQUES PRINCIPALES
0.87 ... 6.9 MS/s
Frecuencia canal de salida
Output channel frequency
Fréquence canal de sortie
45 - 862 MHz
Conax, Cryptoworks, Irdeto,
KeyFly, Mediaguard, Nagravision,
Viaccess, etc.
CAM
(Conditional Access Module)
Lazo derivación entrada QAM
QAM input tap-loop
Boucle dérivation entrée QAM
Conector de programación
Programming connector
Connecteur de programmation
LEDs de control
Control LEDs
LEDs de contrôle
Hembrillas cascada alimentación DC
DC power cascade sockets
Embases cascade alimentation CC
Lazo Vídeo/Audio (aplicación en
sistemas de encriptado)
Video/Audio loop (application in
scrambling systems)
Boucle Vidéo/Audio (application en
systèmes de cryptage)
Lazo acoplamiento salida
Output coupling loop
Boucle multiplexage sortie
1
2
3
5
6
7
Slot para CAM
Slot for CAM
Slot pour CAM
8
Bases cascada bus local IKUSUP
IKUSUP local bus cascade sockets
Embases cascade bus local IKUSUP
(VSB) : Banda Lateral Vestigial
Vestigial Side Band
Bande Latérale Residuelle
Adjacent channels : YES
Model
Ref.
TV System
Audio Mode
IKUSUP bus
CRC-011
4097
B/G/D/K/I/L
(VSB)
Mono
No
CRC-121
4441
D/K/I/L
(VSB)
Mono
Yes
Módulos Receptores con Interfaz Común
Receiving Modules with Common Interface
Modules Récepteurs avec Interface Commune
●
●
●
●
●
2 y 6 : No en modelo CRC-011 /
2 and 6 : No in CRC-011 model
/ 2 et 6 : Non au modèle CRC-011
4
*
Módulo CAM incluido /
CAM in
cluded
/ CAM inclus
120506B
IKUSI — Angel Iglesias, S.A.
Paseo Miramón, 170 - 20009 San Sebastián - SPAIN Tel.: +34 943 44 88 00 Fax: +34 943 44 88 11 [email protected]
www.ikusi.com
8. LEDs de control
LED
SYNC
:
- Luce verde permanente si el receptor
opera de manera apropiada: la cadena
TV seleccionada es presentada correc-
tamente en el canal TV de salida progra-
mado.
- Parpadea verde si el receptor no opera
apropiadamente como se ha descrito.
- Si está apagado y el led STATUS par-
padea rápido rojo: error de
firmware
.
LED
STATUS
:
(En el momento de conectar la alimenta-
ción es normal que parpadee rojo durante
medio minuto).
- Está apagado: el módulo funciona co-
rrectamente.
- Luce rojo permanente: módulo defectuoso.
- Parpadea rápido rojo: error de
firmware
.
Cuando se instala el bus local IKUSUP,
el led parpadea rojo durante el proceso de
autodireccionamiento.
8. Control LEDs
LED
SYNC
:
- Lights up permanently green if the receiver
operates appropriately: the selected TV
station is presented correctly on the
programmed output TV channel.
- Flashes green if the receiver does not
operate appropriately as described.
- If it is off and the led STATUS flashes
red quickly: firmware error.
LED
STATUS
:
(It is normal that It flashes red for half
minute just after powering on).
- Is off: the module works correctly.
- Lights up permanently red: module
damaged.
- Flashes quickly red: firmware error.
When the IKUSUP local bus is installed,
the led flashes red during self-addressing
process.
8. LEDs de contrôle
LED
SYNC
:
- S'illumine verte en permanence si le
récepteur fonctionne bien : la chaîne TV
sélectionnée est présentée correctement
sur le canal TV de sortie programmé.
- Clignote verte si le récepteur ne fonctionne
pas bien comme il a été décrit.
- Si elle est éteinte et la led STATUS clignote
rapidement rouge : erreur de
firmware
.
LED
STATUS
:
(C'est normal qu'elle clignote rouge pendant
demie minute à la mise sous tension).
- Est éteinte : le module marche
correctement.
- S'illumine rouge en permanence : modu-
le défectueux.
- Clignote rapidement rouge : erreur de
firmware
.
Lorsqu'on installe le bus local IKUSUP, la
led clignote rouge pendant le processus
d'auto-adressage.
QAM IN
SYNC
STATUS
+12V
RF OUT
CAM
QAM IN
SYNC
STATUS
+12V
RF OUT
CONTROL
QAM IN
SYNC
STATUS
+12V
RF OUT
CONTROL
QAM IN
SYNC
STATUS
+12V
RF OUT
CONTROL
VLNB
QAM IN
SYNC
STATUS
+12V
RF OUT
CONTROL
CRC-01
1
DIGITAL
CABL
E
RECEIVER
CRC-01
1
DIGITAL
CABL
E
RECEIVER
CRC-01
1
DIGITAL CABLE
RECEIVER
CRC-01
1
DIGITAL CABLE
RECEIVER
CONTROL
CAM
CAM
CAM
CAM
CRC-01
1
DIGITALCABLE
RECEIVER
SPI-300
11. Lazo Vídeo/Audio /
Video/Audio Loop
/ Boucle Vidéo/Audio
Las aperturas y cierres del Lazo Vídeo (5
↔
6) y del Lazo Audio (1
↔
2
y 3
↔
4) se controlan separadamente por software, desde el programador
utilizado (SPI-300 ó PC).
Video Loop (5
↔
6) and Audio Loop (1
↔
2 and 3
↔
4) are switched under
control software from the programming unit used (SPI-300 or PC).
La Boucle Vidéo (5
↔
6) et la Boucle Audio (1
↔
2 et 3
↔
4) s'ouvernt et
se ferment par logiciel depuis la commande utilisée (SPI-300 ou PC).
- Salida vídeo /
Video output
/ Sortie vidéo: 1 Vpp
- Entrada vídeo /
Video input
/ Entrée vidéo: 0.9 ... 1.1 Vpp
- Salida audio /
Audio output
/ Sortie audio: 0 ... 2.0 Vpp
- Entrada audio /
Audio input
/ Entrée audio: 0.5 ... 1.0 Vpp
1 :
Audio R — Entrada /
Input
/ Entrée
2 :
Audio R — Salida /
Output
/ Sortie
3 :
Audio L — Entrada /
Input
/ Entrée
4 :
Audio L — Salida /
Output
/ Sortie
5 :
Video
— Entrada /
Input
/ Entrée
6 :
Video
— Salida /
Output
/ Sortie
1 , 3 :
Audio Mono — Entrada /
Input
/ Entrée
2 , 4 :
Audio Mono — Salida /
Output
/ Sortie
(
)
10. Programación de los receptores
●
La
programación local
se lleva a cabo
con el mando
SPI-300
(vers. firmware
2.15 ó superior). El proceso de progra-
mación se describe en la correspondien-
te guía de utilización.
●
La
programación remota*
sólo puede
llevarse a cabo si la cabecera tiene ins-
talada una unidad de control
HMS
. Se
realiza desde un PC con un navegador
web estándar.
*
Vía GSM, Internet o red LAN. Sólo posible
en el receptor con IKUSUP (modelo CRC-
121).
10. Programming the receivers
●
Local programming
is carried out with
the
SPI-300
Programming Unit (firmware
vers.: 2.15 or later). Programming
processes is described in the
corresponding user's guide.
●
Remote programming*
may be carried
out only if an
HMS
control unit is installed
in the headend. It is performed through
a PC with a standard web browser.
*
Via GSM, Internet or LAN. Possible only
for the receiver with IKUSUP (CRC-121
model).
10. Programmation des récepteurs
●
La
programmation locale
est réalisée
à l'aide de la Commande
SPI-300
(vers.
firmware 2.15 ou ultérieure). La procédure
de programmation est décrite dans le
guide d'utilisation correspondant.
●
La
programmation à distance*
seulement est possible si une unité de
contrôle
HMS
est installée dans la station
de tête. Elle est réalisée depuis un PC
avec un navigateur web standard.
*
Vía GSM, Internet ou réseau LAN. Seulement
possible pour le récepteur avec IKUSUP
(modèle CRC-121).
SPI-300
ER-0149/1996
1
2
4
6
5
3
+V
QAM IN
OUTPUT
OUTPUT TEST
-30 dB
GSM
GPRS
RF IN
(Headend Tapped Signal)
GSM
RTB /
PSTN
/ RTC
Modem
HMS