![Ikegami MKC-310HD Operation Manual Download Page 42](http://html1.mh-extra.com/html/ikegami/mkc-310hd/mkc-310hd_operation-manual_2042099042.webp)
42
5.1.2
Setting
Measure the SYNC output waveforms of the CCU master and slave and adjust the
PHASE so that the H/V phases match. When adjusting, adjust the slave side (side on
which the GENLOCK connector is connected). Phase adjustment is not required on the
Master side.
5.2
Manual Setting a Metering Frame
You can change the range of a metering frame as desired. By adjusting a metering frame,
a video can automatically be adjusted in keeping with the use environment.
5.2.1
Setting
Select [AE Mode]→[Area Select]→[USER..] from the menu and press the SET button.
The
system goes to the manual setting screen for a metering frame
.
Possible to set the position and size of the
metering frame.
When setting is finished, select
QUIT and press the SET button to finish setting.
Master SYNC
Slave SYNC
Quit
Position
Size