Ikegami HTM-1917R Operation Manual Download Page 1

MODEL

HTM-1917R

HDTV/SDTV MULTI FORMAT
COLOR MONITOR

OPERATION MANUAL

Summary of Contents for HTM-1917R

Page 1: ...MODEL HTM 1917R HDTV SDTV MULTI FORMAT COLOR MONITOR OPERATION MANUAL ...

Page 2: ......

Page 3: ...n subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user will be required at his own expense to take whatever measures may be required to correct the interference Instructions for Disposal of Elec...

Page 4: ...e power outlet This is a safety feature If you are unable to insert the plug into the outlet contact your electrician to replace your obsolete outlet Do not defeat the safety purpose of the grounding type plug 3 When connecting and disconnecting the power cable be sure to hold the plug 4 Do not allow anything to rest on the power cord Do not place this television equipment where the cord will be a...

Page 5: ...Y INSTRUCTION 5 Repair 1 Unplug this television monitor from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the power cord or plug is damaged or frayed b If liquid has been spilled into the television c If the television monitor has been exposed to rain or water d If the television does not operate normally by following the operating instru...

Page 6: ...me the CRT may burn in the image 6 Avoid using or storing this unit in the following places Hot 40ºC or more or cold 0ºC or less places Especially where this unit may be exposed to the direct rays of the sun the cabinet may deform and the fluorescent screen of the CRT may deteriorate Humid and dusty places Places where there is considerable vibration Places exposed to rain or water When storing or...

Page 7: ... Subjecting the CRT to direct sunlight for a long period of time deteriorates the florescent faces of the CRT So avoid use outdoors 5 Avoid exposing to high luminance fixed image for long periods of time Take care as this will cause burning of the CRT Also avoid displaying remote numbers in the remote entry state remote numbers are displayed when the wireless remote controller is used for long per...

Page 8: ...oller Parts 14 4 3 1 Names and functions of front panel parts 14 4 3 2 Names and Functions of Drawer Panel Controls 17 4 4 Storing and Changing Data in the Memory 21 4 4 1 Storing and changing the PRESET data 21 4 4 2 Changing and storing the FILE DATA 22 4 5 Types of Markers 23 4 6 Adjustment Procedure 24 4 6 1 Adjusting the brightness 24 4 6 2 Adjusting the contrast 24 4 6 3 Adjusting the white ...

Page 9: ...rcuit the optional multi format SDI module AV or AVD type which sup ports embedded audio output can extract and output the audio signal multiplexed with HD SDI signal or SD SDI 4 2 2 signal The module is available in two types in terms of its audio output AV type producing 2 channel analog out put output channel to be set in MENU and AVD type producing AES EBU digital 8 channel output Embedded aud...

Page 10: ...rs is turned on at once Structure with enhanced maintenance and expendability The signal processing module including optional modules are of the plug in type which can be easily disconnected and connected from the back without the need to remove any cover thus allowing easy mainte nance Besides the DKM 511B multi format SDI module and analog component signal YPbPr module optional modules can be ad...

Page 11: ...d 120 cd m2 in screen center 3 Preset contrast More than 120 cd m2 Factory setting 4 Maximum luminance a SDTV 4 3 170 cd m2 typ b HDTV 16 9 240 cd m2 typ 100 window signal input brightness PRESET contrast MAX 2 1 4 Deflection Sync System 1 16 9 display size a NORMAL 16 9 size within effective CRT screen frame b UNDER 350 W x 197 H mm 2 Deflection a SDTV NORMAL SCAN 4 3 16 9 UNDER SCAN 4 3 16 9 b H...

Page 12: ...mmable ROM RAM 32KB static RAM 2 Battery backup Memory backup time 10 years or longer Battery BR2330 1HF lithium battery 2 1 7 Applicable Standards 1 Safety standards Conforms to UL1950 2 Electromagnetic interference FCC Class A 3 X ray radiation DHHS 2 2 Individual Specifications DKM 511B multi format SDI 2 input module and YPbPr RGB 1 input module are equipped as standard 2 2 1 YPbPr RGB input m...

Page 13: ...witching 3 Sampling frequency 48kHz Synchronized with video clock Analog audio output AV type Analog audio level 0dbs 0 775Vrms 1 Output terminal XLR 5 32 type Canon 5 pin male 2 Line output Analog audio 2 channel Active no transformer balanced output type 3 Rated output level 4dBs Load impedance 10kΩ At 20dBFS digital audio level 4 Max Output level 24dBs Load impedance 10kΩ At 0dBFS digital audio...

Page 14: ...level meter DKM 511 AV AVD is required 5 DAM 508 8 channel embedded audio level meter DKM 511 AV AVD is required 6 DK 801A 4 2 2 degital component module 7 DE 801 NTSC 3 line comb decoder module 8 DE 811 NTSC PAL B general purpose decoder module 9 SRC 301Z Serial remote controller By connecting various monitors by the loop through method up to 99 types of monitors can be remote controlled 10 RCT 3...

Page 15: ...T CONT 1 2 3 DELAY TEST A B C WARNING OVER LOAD NO BURST PARALLEL FUSE 6 25A 250V AC IN A C 1 0 0 1 2 0 V A C 2 0 0 2 4 0 V MAIN POWER FUSE 625A 250V AC IN A C 1 0 0 1 2 0 V A C 2 0 0 2 4 0 V MAIN POWER CH A CH B CH A CH 2 1 CH 3 4 CH 5 6 CH 7 8 MONITOR OUT AIS EBU OUT DKM501AVD CH B CH A MONITOR OUT CH B Y G Pb B CH C Pr R SYNC CH A PARALLEL INPUT SELECT FILE 390 1 5 35 1 5 390 1 5 222 1 20 399 1...

Page 16: ...LEL FUSE 6 25A 250V AC IN A C 1 0 0 1 2 0 V A C 2 0 0 2 4 0 V MAIN POWER FUSE 625A 250V AC IN A C 1 0 0 1 2 0 V A C 2 0 0 2 4 0 V MAIN POWER CH A CH B CH A CH 2 1 CH 3 4 CH 5 6 CH 7 8 MONITOR OUT AIS EBU OUT DKM501AVD CH B CH A MONITOR OUT CH B Y G Pb B CH C Pr R SYNC CH A PARALLEL INPUT SELECT FILE 390 1 5 35 1 5 390 1 5 222 1 20 399 1 ø20 ø22 515 1 5 449 6 1 27 Option module MK 1905 16 9MASK DAM...

Page 17: ...he MENU 1 3 1035i 1080i item also needs to be set Switch YPbPr RGB at the MENU 1 4 item If not adopting the loop through connection method connect the terminated plug EXT SYNC signal input If inputting the YPbPr RGB signal or component signal by external sync input the external sync signal here If not adopting the loop through connection method connect the terminated plug PARALLE REMOTE signal inp...

Page 18: ...r of channels out of four paired channels in the MENU and output 2 channel analog audio signal from this connector Use XLR 5 11C or equivalent as an output connector Pin function Pin 1 GND Pin 2 Odd channel hot output Pin 3 Odd channel cold output Pin 4 Even channel hot output Pin 5 Even channel cold output When active balanced system output is used in unbalanced state connect the cold side to GND...

Page 19: ...SDI B output The SD SDI signal input to the B channel is output from here The signal selected at the monitor can also be output from here by setting the connector inside the module Setting Method NORMAL Default MONITOR OUT EL 102 EL 101 EL 102 EL 101 Decorder module NTSC 3 line comb decorder module DE 801 NTSC PAL general purpose decoder module DE 811 CH A CH A CH B CH C NTSC NTSC PAL B analog com...

Page 20: ...tch between channels A and B When Pins 5 6 and 15 are all OPEN with DE 801 mounted the analog composite will be selected 7 MONO ON Connect to Pin 1 to switch the COLOR MONO setting to MONO 8 RGB ON Connect to Pin 1 to switch the YPbPr RGB setting to RGB 9 EXT SYNC ON Connect to Pin 1 to switch the analog input sync to external sync EXT SYNC Connect to Pin 1 to switch the aspect 4 3 16 9 setting to...

Page 21: ...s switch continuously has no effect release and press again 2 to 3 minutes later POWER switch LED Switch for turning the monitor power ON OFF The LED is ON when the power is turned ON Always turn ON the MAIN POWER switch on the rear panel when starting the monitor Normally turn ON OFF using this switch WARNING POWER DEGAUSS OVER LOAD NO BURST 4 User Adjustment 4 1 Power Supply FUSE 6A250V AC IN AC...

Page 22: ... YPbPr RGB B SDI A or SDI B irrespective of the format it is switched automatically together with the channel switching DIGITAL switch Set to ON when selecting the MULTI SDI HD SDI or SD SDI module The switching method differs as follows according to the mounting state of the SDI module a When only one SDI module is mounted Set the DIGITAL switch to ON b When two SDI modules are mounted MULTI SDI ...

Page 23: ...ubjected to either filter processing COLOR MONO SPLIT When the MONO switch is pressed for 2 to 3 sec onds the split screen upper half of the screen is color while the lower half is black white mode will be set APT switch Turn ON theAPT switch when correcting aperture The aperture function does not work for YPbPr RGB in put SDTV format signal and SD SDI 4 2 2 format signal ASPECT switch Aspect rati...

Page 24: ...trol The control pops out and is switched to the MANUAL state with each press the LED lights By rotating the control in this state the manual data can be varied HUE operates only for the NTSC composite signal CHROMA manual control This control serves as a MANUAL PRESET data selection switch as well as a manual data variable control The control pops out and is switched to the MANUAL state with each...

Page 25: ... the lumi nance signal and chrominance signal When the LED is ON the regular matrix close to the one in home television is used SET UP switch When set to ON SET UP side LED is ON the vertical deflection is reduced facilitating adjust ments of the black balance R G B BACK GROUND FORCED COL MONO switch Functions only when the NTSC decoder is mounted FORCED MONO Function COL MONO SWITCH SWITCH AUTO C...

Page 26: ...e HUE MANUAL switch on the front panel is ON set it to PRESET The switch is enabled only when the NTSC composite signal is selected c CHROMA PRESET switch When the CHROMA MANUAL switch on the front panel is ON set it to PRESET d BRGHITNESS PRESET switch When the BRIGHT MANUAL switch on the front panel is ON set it to PRESET e CONTRAST PRESET switch When the CONT MANUAL switch on the front panel is...

Page 27: ...for adjusting the low light balance green component For details of the adjustment refer to 4 6 3 R BACKGROUND switch Switch for adjusting the low light balance blue component For details of the adjustment refer to 4 6 3 G GAIN switch Switch for adjusting the high light white balance green component For details of the adjustment refer to 4 6 3 B GAIN switch Switch for adjusting the high light white...

Page 28: ... 1 switch Set this switch to ON to output or store data in FILE 1 2 7 FILE 2 switch Set this switch to ON to output or store data in FILE 2 2 8 FILE 3 switch Set this switch to ON to output or store data in FILE 3 2 9 MENU switch Switch to call various menus 3 0 ENT switch Switch to execute MENU operations 3 1 ESC switch Switch to exit MENU 3 2 U DISPLAY switch Not available in this version 3 3 AS...

Page 29: ...Y SELECT FILE STORE FILE CHANGE PRESET FORCED COL MONO MATRIX IN SET UP EXT SYNC RE SC HEIGHT MIDTH APT EXPAND V CENT H CENT MK PHASE ROTATION BACK GRAND BLIGHT HUB ASP CONT CHROMA AUTO SET UP GAIN CREAR MENU ENT ESC U DISPLAY 1 2 3 DISPLAY SELECT FILE STORE FILE CHANGE PRESET FORCED COL MONO MATRIX IN SET UP EXT SYNC RE SC HEIGHT MIDTH APT EXPAND V CENT H CENT MK PHASE ROTATION BACK GRAND BLIGHT ...

Page 30: ...state data to FILE 3 and changing the color temperature DISPLAY SELECT FILE STORE FILE CHANGE PRESET FORCED COL MONO MATRIX IN SET UP EXT SYNC RE SC HEIGHT MIDTH APT EXPAND V CENT H CENT MK PHASE ROTATION BACK GRAND BLIGHT HUB ASP CONT CHROMA AUTO SET UP GAIN CREAR MENU ENT ESC U DISPLAY 1 2 3 FILE STORE FILE 1 2 3 FILE STORE FILE 1 2 3 DISPLAY SELECT FILE STORE FILE CHANGE PRESET FORCED COL MONO ...

Page 31: ... 14 9 marker shadow Active screen area 14 9 marker 14 9 shadow 4 3 marker shadow Active screen area 4 3 marker 4 3 shadow 4 3 shadow Active screen area 4 3 shadow 13 9 marker shadow Active screen area 13 9 marker 13 9 shadow 13 9 shadow Active screen area 13 9 shadow 4 3 marker Active screen area 4 3 marker 14 9 shadow Active screen area 14 9 shadow 13 9 marker Active screen area 13 9 marker 4 3 m...

Page 32: ...g a luminance meter and adjust the contrast to 120nit cd m2 or 35fL 3 Adjusting the white balance a White balance The monitor has four files to store white balance data The four files are set to the following color temperatures as default REFERENCE 6500ºC FILE 1 6500ºC FILE 2 9300ºC FILE 3 6500ºC The white balance can be adjusted using an ana lyzer or the optional ASP 80 discontinued 100 for autom...

Page 33: ...adjust the R BACKGROUND data so that the red line at Part B in the figure illumi nates slightly Return the SET UP and SCREEN switches to their original settings OFF and do not move R BACKGROUND thereafter Setting CONTRAST Set CONTRAST to MANUAL and contact the probe at the center of the window signal displayed on the screen Preset the luminance value to approx 5nit cd m2 or 1 5fL using MANUAL op e...

Page 34: ... Component signal Input signal Input the 100 color bar signal to the YPbPr in put Starting Set the screen to blue only using the SCREEN switch As the luminance difference is hard to discern when the screen is bright dim the surroundings as much as practical and lower the BRIGHTNESS manually until the blue signal is slightly visible This will help make more accurate adjustment Adjusting CHROMA Adju...

Page 35: ...hing channels Changing input signal format Switching SCAN Switching ASPECT c Adjustment procedure Perform the following adjustment once for each sig nal format Input signal Check the MENU 1 format is set properly to the signal format to be changed For details of the format setting refer to 4 7 3 in this manual The input signal should be the one such as monoscope signal which can display video on t...

Page 36: ...NG OK 8 Adjusting the screen size a Screen size Set the screen size using HEIGHT and WIDTH The following four sizes can be set for these two data per signal format three sizes for HDTV In dividual data is provided for all formats which can be input for the following sizes SCAN switch NORMAL SCAN UNDER SCAN ASPECT switch 4 3 SCAN 16 9 SCAN b Precautions As the HEIGHT and WIDTH settings are stored a...

Page 37: ...eter If you are working with a signal not having a circle pat tern adjust the 93 marker size so that it becomes identical to the size shown below as a guide Before proceeding to adjust another SCAN size be sure to press the CHANGE PRESET switch now to store the current data HEIGHT WIDHT HEIGHT WIDHT SDTV4 3 NORMAL Size SD HD 16 9 NORMAL Size 93 area 93 area e Adjustment procedure 3 HDTV 4 3 SCAN A...

Page 38: ...er 01 to 99 DEGAUSS TM Setting the degauss ON timer 0 to 9 MENU3 SELECT FILE Selecting FILE REF FILE 1 2 3 CHANGE DATA STORE FILE Storing FILE REF FILE 1 2 3 CHANGE FILE Setting AUTO MANUAL file change LOAD FACTORY Setting to restore default factory setting MENU4 STATUS Displaying status information of each data STATUS MENU5 PASSWORD LOCK Setting the data password lock LOCK MENU6 ZERO CALIBRATION ...

Page 39: ...G BKG 52 4 V CONV B BKG 48 5 TRAPE 45 2 APT OFF SIDE P 40 3 NEXT MENU MENU5 LOCK UNLOCK ENTER PASSWARD ABCDEFGHIJKLMNOPQRSTUVWX YZ123456789 PASSWORD NEXT MENU SELECT ENT EXIT ESC MENU6 SETUP ASP 80 1 ZERO CARIBRATION 2 AWB 6500k 3 AWB 9300k 4 AWB USER DATA 5 MEASUREMENT MEMORY 6 REAL TIME MEASUREMENT NEXT MENU SELECT ENT EXIT ESC MENU7 AUDIO 1 LINE OUT CH CH1 2 2 LED ENABLE CH1to8 3 LED DIMMER HIG...

Page 40: ...t up If the input signal is 1035i 60 or 1080i 60 the for mat should be set individually in the following step Default setting is HDTV Format setting of 1035i 60 and 1080i 60 of RGB YPbPr input Set the scan line number to 1035i or 1080i Default setting is 1080i 60 Setting of RGB and YPbPr of RGB YPbPr input Set the RGB YPbPr input signal to RGB or YPbPr Default setting is YPbPr Format setting of in...

Page 41: ...e until the degauss function starts after the power is turned on Setting Operation Start Time Setting Operation Start Time 0 4 0 seconds 5 6 5 seconds 1 4 5 seconds 6 7 0 seconds 2 5 0 seconds 7 7 5 seconds 3 5 5 seconds 8 8 0 seconds 4 6 0 seconds 9 8 5 seconds 5 Description of MENU 3 Functions FILE selection Selection of destination FILE AUTO MANUAL setting for FILE change Setting to restore def...

Page 42: ...ected LOCK MODE Password menu Password input LOCK MODE After setting the 4 digit password set ENT switch to ON Currently selected LOCK MODE The currently selected LOCK MODE is displayed here UNLOCK All data can be changed with the LOCK released ALL LOCK Change of all PRESET data and switching of FILE are disabled PRESET FILE LOCK PRESET and FILE data are locked Switching of FILE is allowed Passwor...

Page 43: ...re the color temperature luminance and ras ter luminance of the user setting The results can be stored as USER DATA if neces sary Measurable ranges are as follows Luminance 10 190cd Raster luminance 0 01 0 99cd Color temperature x y coordinates 0 250 0 380 Real time color temperature and luminance measurement Color temperature and luminance are measured for real time display of the readings The fu...

Page 44: ...t APT switch to ON and resume the operation MARKER ON Cause This message is displayed when MK PHASE PRESET switch is pressed while MARKER switch is OFF Action Set MARKER switch to ON and resume the operation STORE FILE OFF Cause This message is displayed when CHANGE PRESET switch is pressed while FILE 1 to FILE 3 are blinking by pressing STORE FILE switch Press STORE FILE switch to cancel the sele...

Page 45: ...LEL YPbPr GBR MONITOR OUT MONITOR OUT CH A INPUT CH B HD 4 2 2 SDI SDI 4 2 2 NTSC AUDIO LINE OUT DKM 511AV DKM 511AVD AES EBS OUT 1 2 3 4 5 6 MODEL NO MODULE NAME SLOT WIDTH DK 801A 4 2 2 Digital Component Module 1 DKM 511A B Multi Format Digital Module 1 DKM 511 AV Multi Format Digital Module with Embedded Analog Audio output 2 DKM 511 AVD Multi Format Digital Module with Embedded Audio AES EBU o...

Page 46: ...r for HTM 1917R 2050R The parts marked are supplied with the slide rail marks are attachments for the side rail SLIDE RAIL RACKSIDE BRACKET MONITOR MCB4 8FZ HOLE CAP RACK METAL MCB4 12FZ N1H5FZ RACK SCREWL WASHER SLIDE RAIL MONITOR SIDE RS 2020S SLIDE RAIL ...

Page 47: ...0A Infrared Remote Controller REMOTE CONTROL RCT 30A CHANGE PRESET WHITE BALANCE MENU FILE R G B COMB APT SYNC DEGAUSS MONO INPUT DELAY SCAN END 7 8 9 CALL 4 5 6 0 1 MONITOR SELECT 2 3 ENT ESC MARKER CLEAR ENT 54 5 49 5 18 3 182 5 19 ...

Page 48: ...0 1 2 3 A COMPOSITE B C Y C A B TEST A B A B OFF ON COLOR MONO TRAP D PAL COMB S PAL OFF ON 4 3 16 9 NOR UNDER OFF ON OFF ON FILE DEGAUSS S1 S2 REMOTE OUT DC IN POWER 9V TYPbPr RGB HD SDI BLUE APT SCAN 30 40 110Ⳳ1 45 2Ⳳ1 37 2Ⳳ1 240Ⳳ1 220Ⳳ1 10 5 230 240Ⳳ1 100 103 Cable Length Approx 1900mm SRC 301A SERIAL REMOTE CONTROLLER ...

Page 49: ...TORY in MENU 3 4 DATA HUE CHROMA BRIGHT CONT G GAIN B GAIN R BKG G BKG B BKG APT ROTATION 4 3 UNDER 4 3 NORMAL HD 4 3 16 9 UNDER 16 9 NORMAL 4 3 UNDER 4 3 NORMAL HD 4 3 16 9 UNDER 16 9 NORMAL HD 4 3 16 9 WIDTH HEIGHT MK PHASE H CENT V CENT TRAPEZOID SIDE PIN HD 4 3 16 9 HD 4 3 16 9 REF FILE 1 FILE 2 FILE 3 DATA 480i 575i 1035i 1080i 720p 4 3 means HD4 3SCAN in the case of HDTV 4 3 UNDER 4 3 NORMAL...

Page 50: ......

Page 51: ...ition or contents in whole in part any manner is prohibited Specifications and design are subject to change without notice Published by Ikegami Tsushinki Co Ltd Nov 2006 by Utsunomiya Factory of Ikegami Tsushinki Co Ltd OPERATION MANUAL HDTV SDTV MULTI FORMAT COLOR MONITOR OMH1917R U Edited by Koyo 21 Co Ltd 06 nov ...

Page 52: ...626 NORTHEAST OFFICE 37BrookAvenue Maywood New Jersey 07607 Phone 201 368 9171 Fax 201 569 1626 WEST COAST OFFICE 20603 Earl Street Torrance California 90503 Phone 310 370 2400 Fax 310 370 7131 MIDWEST OFFICE 747 Chrch Road Unit C4 Elmhurst IL 60126 Phone 630 834 9774 Fax 630 834 8689 SOUTHEAST OFFICE 5200N W 33rdAvenue Suite 111 Fort Landerdale FI 33309 Phone 945 735 2203 Fax 945 735 2227 Propert...