Draco vario
DisplayPort
1.2
Technical Data
111
12.2.2 Fiber
NOTICE
Transmission problems
Routing over an active network component, such as an ethernet hub, switch, or router is not allowed.
Operation with several patch fields is possible.
Establish a point-to-point connection.
Avoid routing Cat X cables along power cables.
Type of Interconnect Cable*
Type of cable
Specification
Single-mode 9
μm
•
Two fibers 9
μm
•
I-V(ZN)H 2E9 (in-house patch cable)
•
I-V(ZN)HH 2E9 (in-house breakout cable)
•
I/AD(ZN)H 4E9 (in-house or outdoor breakout cable, resistant)
•
A/DQ(ZN)B2Y 4G9 (outdoor cable, with protection against rodents)
Multi-mode 50
μm
•
Two fibers 50
μm
•
I-V(ZN)H 2G50 (in-house patch cable)
•
I/AD(ZN)H 4G50 (in-house or outdoor breakout cable, resistant)
* Cable notations according to VDE
Maximum Transmission Range for Video and USB-HID Signals (End-to-End Connection)
NOTICE
Transmission ranges when using add-on modules with transparent USB
When using L474/R474 add-on modules with transparent USB, the binding specifications stated in the
data sheets of the add-on modules apply.
Type of cable
Bandwidth
Maximum transmission range
Single-Mode 9
μm
1G
10,000 m (32,808 ft)
Single-Mode 9
μm
3G
5,000 m (16,404 ft)
Multi-Mode 50
μm
(OM3)
1G/3G
1,000 m (3,280 ft)
Multi-Mode 50
μm
1G/3G
400 m (1,312 ft)
When using single-mode SFPs with multi-mode fiber optic cables, the maximum transmission range can
usually be doubled.
Type of Connector
Connector
Type
Plug-in connector
LC-Connector