Draco vario
DisplayPort
1.1
Technical Data
105
9.4 Power Supply, Current Draw and Power Consumption
NOTICE
Overheating of the power supply units
In case of having redundant power supply units, the maximum current must not exceed the value of one
of the two power supply units due to the heat dissipation.
9.4.1 Power Supply of the Chassis (AC)
Product type
Maximum current draw Maximum voltage AC
Frequency
474-BODY2N
700 mA
100 V to 240 V
50/60 Hz
474-BODY2BPF
700 mA
100 V to 240 V
50/60 Hz
474-BODY6R-R1
1,500 mA
90 V to 264 V
47-63 Hz
474-BODY6BP*
1,300 mA
100 V to 240 V
50/60 Hz
474-BODY6BPF*
1,300 mA
100 V to 240 V
50/60 Hz
474-BODY21/4U
4,000 mA
2x 100 V to 240 V
50/60 Hz
* The 474-BODY6BP and 474-BODY6BPF chassis require a fan should the extender modules exceed a
current draw of 6.000 mA. We recommend mounting the chassis fan 474-6FAN. Please refer to the
mounting instructions.
9.4.2 Power Supply of the Chassis (DC)
Product type
Maximum current draw Maximum voltage DC
474-BODY2
3,000 mA
5 V
474-BODY2R
3,000 mA
5 V
474-BODY2N
5,000 mA
5 V
474-BODY2BPF*
5,000 mA
5 V
474-BODY4
5,000 mA
5 V
474-BODY4R
5,000 mA
5 V
474-BODY6R-R1
12,000 mA
5 V
* The 474-BODY2BPF chassis require a fan should the extender modules exceed a current draw of
2,500 mA. We recommend mounting the chassis fan 474-6FAN. Please refer to the mounting
instructions.
9.4.3 Current Draw of the KVM Extenders Modules, Series 48x
Cat X 1G
Cat X 1G
redundant
Fiber 1G
Fiber 1G
redundant
Fiber 3G
Fiber 3G
redundant
CPU-Modul SH
820 mA
910 mA
800 mA
930 mA
750 mA
880 mA
CON-Modul SH
1.080 mA
1.180 mA 1.040 mA 1.150 mA 990 mA
1.120 mA
CPU-Modul DH
1.050 mA
1.200 mA 1.050 mA 1.200 mA 1.150 mA 1.300 mA
CON-Modul DH
1.300 mA
1.450 mA 1.300 mA 1.450 mA 1.490 mA 1.640 mA