![Ihse Draco tera flex Cat X 1G K480-C120 User Manual Download Page 67](http://html.mh-extra.com/html/ihse/draco-tera-flex-cat-x-1g-k480-c120/draco-tera-flex-cat-x-1g-k480-c120_user-manual_623701067.webp)
Draco tera flex
Configuration via OSD
67
7.3
System Settings
7.3.1
Setting System Configuration
The parameters for the system configuration are set in this menu:
Fig. 63
OSD Menu Configuration - System
The following parameters can be configured:
System
Field
Entry
Description
Device
Text
Enter the device name of the matrix (default: SWITCH_01)
Name
Text
Enter the name of the configuration that is used to save the
current settings (default: Standard)
Info
Text
Additional text field to describe the configuration (default:
Factory settings)
Sub Matrix
Y
If the matrix is defined as a sub matrix in the OSD, the user will
lose control. Control can be recovered by using the keyboard
command
<Hot Key>
,
<s>
,
<o>
. The OSD for the matrix that
has been defined as sub matrix will be reopened.
N
Function not active (default)
Load Default
Y
Starting the matrix after a restart or a switch-on with the default
configuration.
N
Starting the matrix after a restart or a switch-on with the last
saved configuration (default).