Specifications
Draco tera flex
314
10
Specifications
10.1 Interfaces
10.1.1 RJ45 (Network)
The network communication of the devices requires a 1000BASE-T connection.
The cabling has to be done according to EIA/TIA-568-B (1000BASE-T) with RJ45 connectors at both ends.
All four wire pairs are used in both directions. The cabling is suitable for a full duplex operation. For the
cable connection to a source (computer, CPU), a crossed network cable (cross cable) has to be used.
10.1.2 RJ45 (Interconnect)
The communication between Cat X devices requires a 1000BASE-T connection.
Connector wiring must comply with EIA/TIA-568-B (1000BASE-T), with RJ45 connectors at both ends. All
four cable wire pairs are used in both directions.
10.1.3 Fiber SFP Type LC (Interconnect)
The communication of fiber devices is performed via Gigabit SFPs that are connected to suitable fibers
fitted with connectors type LC (see (chapter 10.2.2, page 316).
NOTICE
The correct function of the device can only be guaranteed with SFPs provided by the manufacturer.
NOTICE
SFP modules can be damaged by electrostatic discharge (ESD).
Please consider ESD handling specifications.