Operation
Draco tera flex
268
5. Press the
<Enter>
key to execute the macro.
The macro will be immediately executed.
If the Macro List should be directly displayed upon opening OSD, activate the option
Show Macro List
in
the menu
Configuration > CON Devices
for the respective CON Devices.
9.2.6
Switching of single EXT Units within Devices
You can independently switch CON Devices and CPU Devices with single EXT Units within configurations
consisting of CON Devices and CPU Devices with multiple EXT Units.
Fig. 203
OSD Menu Switch
To switch a CON Device with a single EXT Unit to a CPU Device with multiple EXT Units, proceed as
follows:
1. Select
Switch
in the main menu.
2. Select the respective CPU Device in the CPU Devices list containing the EXT Unit you want to have
access to.
3. Press the
<F7>
function key on the keyboard. The standard will change into the switching mode for
CON Devices with a single EXT Unit.
4. Select the EXT Unit you want to switch within your CON Device.
5. Press the
<Tab>
key to access the EXT Unit list of the selected CPU Device.
6. Select the CPU EXT Unit you want to switch to.
7. Press the
<Space>
key to execute the switching operation.
Switching of single EXT Units from a Device is only possible in
Video Only
mode. Single EXT Units of a
Device that are already switched will be highlighted with "
!
".