Fig. 27
Status LEDs for power supply voltage, Draco tera 576 port, revision 1
1 LED for power supply voltage
LEDs for Power Supply Voltage
LEDs LED Status
Description
1
Flashing green Stand-by on; main output off, AC input power on.
Green
Stand-by on; main output on, no fault detected.
Flashing
orange
Fault detected: main output OCP (over current protected) or UVP (under
voltage protected) or OVP (over voltage protected).
Orange
Fan fault or OTP (over temperature protected) or stand-by on with
OCP/UVP.
Off
AC input power off.
3.6.3.4 Draco tera 576 Port, Revision 2
Fig. 28
Status LEDs for power supply voltage, Draco tera 576 port, revision 2
1 LED for power supply voltage
LEDs for Power Supply Voltage
LEDs LED Status
Description
1
Flashing green Stand-by on; main output off, AC input power on.
Green
Stand-by on; main output on, no fault detected.
Flashing
orange
Power supply warning event
Orange
Fault detected: main output stand-by output, fan, overtemperature, input
OVP.
Off
AC input power off.