Page 1: ...1 iHealth PT3SBT Wireless No Touch Forehead Thermometer FCC ID SLRPT3SBT IC 10913A PT3SBT...

Page 2: ...applications 8 Contraindications 8 Instruction For Use 8 SYNC TIME AND RESULTS VIA BLUETOOTH 11 Product errors and troubleshooting 12 Body temperature 12 Cleaning and Care 13 Care the probe 13 Mainten...

Page 3: ...bout the temperature reading Keep the thermometer out of reach of children For accidental swallowing of the battery or other components please contact emergency services immediately Batteries must not...

Page 4: ...y cause errors in the reading or even device failure 12 Portable RF communications equipment including peripherals such as antenna cables and external antennas should be used no closer than 30 cm 12 i...

Page 5: ...owing occurred 1 Operation outside of the manufacturer specified subject temperature range 2 Operation outside of the manufacturer specified operating temperature and humidity ranges 3 Storage outside...

Page 6: ...ncluding interference that may cause undesired operation of the device Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maximum or lesser gain a...

Page 7: ...s 4 Measurement range 89 6 109 2 32 42 9 5 Measurement precision 0 4 0 2 within 93 2 107 6 34 42 and 0 5 0 3 for other temperature ranges 6 Resolution 0 1 0 1 7 Clinical reproducibility Within 0 5 0 3...

Page 8: ...ntraindications It is not recommended for people whose measuring part has local lesions such as inflammation trauma postoperative etc Instruction For Use The patient is an intended operator The patien...

Page 9: ...ead If the icon on the thermometer screen is always on the measured temperature data can be uploaded to the smart device Possible reasons for measurement errors include A Measurement distance is great...

Page 10: ...if the battery capacity is too low for measurements the screen will display a single flashing icon and automatically switch OFF after 8 seconds To continue using the device old batteries must be repla...

Page 11: ...ress the button to turn on the thermometer or start one measurement 2 Enable Bluetooth on your Android device 3 When using the thermometer for the first time you should pair the thermometer to the And...

Page 12: ...g Target temperature is beyond range of measurements 89 6 109 2 32 42 9 Environment temperature either exceeds the design range 32 104 0 40 or is unstable Follow the instruction manual and repeat the...

Page 13: ...ermometer casing thoroughly The wiping process preferably lasts 15 seconds Allow at least 5 minutes drying time before taking a temperature After cleaning if the device is not visually clean when obse...

Page 14: ...E Directive If you have any queries please refer to the local authorities responsible for waste disposal Notes Please act according to local laws for disposal of used batteries Take out the battery if...

Page 15: ...h is a trademark of iHealth Labs Inc The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc And any use of such marks by iHealth Labs Inc is under license Calibration T...

Page 16: ...n tested against this SAR limit ELECTROMAGNETIC COMPATIBILITY INFORMATION Frequency range Bluetooth 2402MHz 2480MHz Max EIRP 4 40dBm Table 1 Emission limits per environment Phenomenon Compliance Elect...

Page 17: ...ty terms as below 1 The warranty period for device is one year from date of delivery In case of a warranty claim the date of delivery has to be proven by means of the sales receipt or invoice 2 Repair...

Page 18: ...ict Tianjin 300190 China Tel 86 22 60526161 This product can be used across EU member states EU Regulatory Conformance Hereby iHealth Labs Inc declares that this device is in compliance with the essen...