Product
6/13
Manual i.Sense CF.D - V 1.1
3.2 Specifications
Mechanical Specifications
D x W x H in millimeters
31 x 32 x 84 mm
Weight in grams
Approx. 50 g
Fastening / Assembly
Built into network transmission cable
Case
Black or golden aluminum housing
Interfaces
UART
5V 115200 baud, 8N1, no parity
Ethernet
100 Mbit/s, connection of the line to be measured
Electrical Specifications
Power supply
5 V DC
Rated current
0.15 A
Measurement interval
1s
–
24h
Configuration optionen
-
Measurement interval (in seconds)
-
Measuring frequency/ measuring channel (0 - 9)
-
Output power
Frequency band
868... 886 MHz
Output power
3... 100 mW
-
Risk of destruction
An operating voltage above the voltage specified in the technical data destroys the i.Sense CF.D. Select an operating
voltage that is within the voltage range specified in the technical data.
Be aware of possible disturbances and induced voltages caused by other consumers and/or motors and plan appropriate
safety reserves and countermeasures. Make sure that your power supply is back-proof if the logic and load voltage are
supplied from the same power supply or transformer
C
A
U
TI
ON
!
Ambient conditions
Temperature range
Operation
-20... 40 °C
Storage
-40... 45 °C
Transport
-40... 45°C
Relative humidity
≤ 90%, non
-condensing
Protection
IP 30/ DIN EN 60529
-
Risk of malfunctions
-
Fire
-
Danger of explosion
-
Risk of electric shock
Operate i.Sense CF. D not in water, humid environments or in aggressive, flammable or explosive atmospheres.
W
A
R
N
IN
G!