background image

©2021

ACC-SVN190B-EN

Introduction

Read this manual thoroughly before operating or
servicing this unit.

Warnings, Cautions, and Notices

Safety advisories appear throughout this manual as
required. Your personal safety and the proper
operation of this machine depend upon the strict
observance of these precautions.

The three types of advisories are defined as follows:

WARNING

Indicates a potentially hazardous situation
which, if not avoided, could result in death or
serious injury.

CAUTION

Indicates a potentially hazardous situation
which, if not avoided, could result in minor or
moderate injury. It could also be used to alert
against unsafe practices.

NOTICE

Indicates a situation that could result in
equipment or property-damage only
accidents.

Important Environmental Concerns

Scientific research has shown that certain man-made
chemicals can affect the earth’s naturally occurring
stratospheric ozone layer when released to the
atmosphere. In particular, several of the identified
chemicals that may affect the ozone layer are
refrigerants that contain Chlorine, Fluorine and Carbon
(CFCs) and those containing Hydrogen, Chlorine,
Fluorine and Carbon (HCFCs). Not all refrigerants
containing these compounds have the same potential
impact to the environment. Trane advocates the
responsible handling of all refrigerants-including
industry replacements for CFCs and HCFCs such as
saturated or unsaturated HFCs and HCFCs.

Important Responsible Refrigerant
Practices

Trane believes that responsible refrigerant practices
are important to the environment, our customers, and
the air conditioning industry. All technicians who
handle refrigerants must be certified according to local
rules. For the USA, the Federal Clean Air Act (Section
608) sets forth the requirements for handling,
reclaiming, recovering and recycling of certain
refrigerants and the equipment that is used in these
service procedures. In addition, some states or
municipalities may have additional requirements that
must also be adhered to for responsible management
of refrigerants. Know the applicable laws and follow
them.

W

WA

AR

RN

NIIN

NG

G

P

Prro

op

pe

err F

Fiie

elld

d W

Wiirriin

ng

g a

an

nd

d G

Grro

ou

un

nd

diin

ng

g

R

Re

eq

qu

uiirre

ed

d!!

F

Fa

aiillu

urre

e tto

o ffo

ollllo

ow

w cco

od

de

e cco

ou

ulld

d rre

essu

ulltt iin

n d

de

ea

atth

h o

orr

sse

erriio

ou

uss iin

njju

urry

y..

A

Allll ffiie

elld

d w

wiirriin

ng

g M

MU

US

ST

T b

be

e p

pe

errffo

orrm

me

ed

d b

by

y q

qu

ua

alliiffiie

ed

d

p

pe

errsso

on

nn

ne

ell.. IIm

mp

prro

op

pe

errlly

y iin

nsstta

alllle

ed

d a

an

nd

d g

grro

ou

un

nd

de

ed

d

ffiie

elld

d w

wiirriin

ng

g p

po

osse

ess F

FIIR

RE

E a

an

nd

d E

EL

LE

EC

CT

TR

RO

OC

CU

UT

TIIO

ON

N

h

ha

azza

arrd

dss.. T

To

o a

av

vo

oiid

d tth

he

esse

e h

ha

azza

arrd

dss,, y

yo

ou

u M

MU

US

ST

T ffo

ollllo

ow

w

rre

eq

qu

uiirre

em

me

en

nttss ffo

orr ffiie

elld

d w

wiirriin

ng

g iin

nsstta

alllla

attiio

on

n a

an

nd

d

g

grro

ou

un

nd

diin

ng

g a

ass d

de

essccrriib

be

ed

d iin

n N

NE

EC

C a

an

nd

d y

yo

ou

urr llo

occa

all//

sstta

atte

e//n

na

attiio

on

na

all e

elle

eccttrriicca

all cco

od

de

ess..

W

WA

AR

RN

NIIN

NG

G

P

Pe

errsso

on

na

all P

Prro

otte

eccttiiv

ve

e E

Eq

qu

uiip

pm

me

en

ntt ((P

PP

PE

E))

R

Re

eq

qu

uiirre

ed

d!!

F

Fa

aiillu

urre

e tto

o w

we

ea

arr p

prro

op

pe

err P

PP

PE

E ffo

orr tth

he

e jjo

ob

b b

be

eiin

ng

g

u

un

nd

de

errtta

akke

en

n cco

ou

ulld

d rre

essu

ulltt iin

n d

de

ea

atth

h o

orr sse

erriio

ou

uss iin

njju

urry

y..

T

Te

ecch

hn

niicciia

an

nss,, iin

n o

orrd

de

err tto

o p

prro

otte

ecctt tth

he

em

msse

ellv

ve

ess ffrro

om

m

p

po

otte

en

nttiia

all e

elle

eccttrriicca

all,, m

me

ecch

ha

an

niicca

all,, a

an

nd

d cch

he

em

miicca

all

h

ha

azza

arrd

dss,, M

MU

US

ST

T ffo

ollllo

ow

w p

prre

ecca

au

uttiio

on

nss iin

n tth

hiiss m

ma

an

nu

ua

all

a

an

nd

d o

on

n tth

he

e tta

ag

gss,, ssttiicckke

errss,, a

an

nd

d lla

ab

be

ellss,, a

ass w

we

ellll a

ass tth

he

e

iin

nssttrru

uccttiio

on

nss b

be

ello

ow

w::

••

B

Be

effo

orre

e iin

nsstta

alllliin

ng

g//sse

errv

viicciin

ng

g tth

hiiss u

un

niitt,,

tte

ecch

hn

niicciia

an

nss M

MU

US

ST

T p

pu

utt o

on

n a

allll P

PP

PE

E rre

eq

qu

uiirre

ed

d ffo

orr

tth

he

e w

wo

orrkk b

be

eiin

ng

g u

un

nd

de

errtta

akke

en

n ((E

Ex

xa

am

mp

plle

ess;; ccu

utt

rre

essiisstta

an

ntt g

gllo

ov

ve

ess//sslle

ee

ev

ve

ess,, b

bu

utty

yll g

gllo

ov

ve

ess,, ssa

affe

etty

y

g

glla

asssse

ess,, h

ha

arrd

d h

ha

att//b

bu

um

mp

p cca

ap

p,, ffa

allll p

prro

otte

eccttiio

on

n,,

e

elle

eccttrriicca

all P

PP

PE

E a

an

nd

d a

arrcc fflla

assh

h ccllo

otth

hiin

ng

g))..

A

AL

LW

WA

AY

YS

S rre

effe

err tto

o a

ap

pp

prro

op

prriia

atte

e S

Sa

affe

etty

y D

Da

atta

a

S

Sh

he

ee

ettss ((S

SD

DS

S)) a

an

nd

d O

OS

SH

HA

A g

gu

uiid

de

elliin

ne

ess ffo

orr

p

prro

op

pe

err P

PP

PE

E..

••

W

Wh

he

en

n w

wo

orrkkiin

ng

g w

wiitth

h o

orr a

arro

ou

un

nd

d h

ha

azza

arrd

do

ou

uss

cch

he

em

miicca

allss,, A

AL

LW

WA

AY

YS

S rre

effe

err tto

o tth

he

e a

ap

pp

prro

op

prriia

atte

e

S

SD

DS

S a

an

nd

d O

OS

SH

HA

A//G

GH

HS

S ((G

Gllo

ob

ba

all H

Ha

arrm

mo

on

niizze

ed

d

S

Sy

ysstte

em

m o

off C

Clla

assssiiffiicca

attiio

on

n a

an

nd

d L

La

ab

be

elllliin

ng

g o

off

C

Ch

he

em

miicca

allss)) g

gu

uiid

de

elliin

ne

ess ffo

orr iin

nffo

orrm

ma

attiio

on

n o

on

n

a

allllo

ow

wa

ab

blle

e p

pe

errsso

on

na

all e

ex

xp

po

ossu

urre

e lle

ev

ve

ellss,, p

prro

op

pe

err

rre

essp

piirra

atto

orry

y p

prro

otte

eccttiio

on

n a

an

nd

d h

ha

an

nd

dlliin

ng

g

iin

nssttrru

uccttiio

on

nss..

••

IIff tth

he

erre

e iiss a

a rriisskk o

off e

en

ne

errg

giizze

ed

d e

elle

eccttrriicca

all

cco

on

ntta

acctt,, a

arrcc,, o

orr fflla

assh

h,, tte

ecch

hn

niicciia

an

nss M

MU

US

ST

T p

pu

utt

o

on

n a

allll P

PP

PE

E iin

n a

acccco

orrd

da

an

ncce

e w

wiitth

h O

OS

SH

HA

A,, N

NF

FP

PA

A

7

70

0E

E,, o

orr o

otth

he

err cco

ou

un

nttrry

y--ssp

pe

ecciiffiicc rre

eq

qu

uiirre

em

me

en

nttss

ffo

orr a

arrcc fflla

assh

h p

prro

otte

eccttiio

on

n,, P

PR

RIIO

OR

R tto

o sse

errv

viicciin

ng

g

tth

he

e u

un

niitt.. N

NE

EV

VE

ER

R P

PE

ER

RF

FO

OR

RM

M A

AN

NY

Y S

SW

WIIT

TC

CH

HIIN

NG

G,,

D

DIIS

SC

CO

ON

NN

NE

EC

CT

TIIN

NG

G,, O

OR

R V

VO

OL

LT

TA

AG

GE

E T

TE

ES

ST

TIIN

NG

G

W

WIIT

TH

HO

OU

UT

T P

PR

RO

OP

PE

ER

R E

EL

LE

EC

CT

TR

RIIC

CA

AL

L P

PP

PE

E A

AN

ND

D

A

AR

RC

C F

FL

LA

AS

SH

H C

CL

LO

OT

TH

HIIN

NG

G.. E

EN

NS

SU

UR

RE

E

E

EL

LE

EC

CT

TR

RIIC

CA

AL

L M

ME

ET

TE

ER

RS

S A

AN

ND

D E

EQ

QU

UIIP

PM

ME

EN

NT

T A

AR

RE

E

P

PR

RO

OP

PE

ER

RL

LY

Y R

RA

AT

TE

ED

D F

FO

OR

R IIN

NT

TE

EN

ND

DE

ED

D

V

VO

OL

LT

TA

AG

GE

E..

Summary of Contents for Odyssey BAYLOAMS20

Page 1: ...ment observe all precautions in the literature and on the tags stickers and labels that are attached to the equipment August 2021 A AC CC C S SV VN N1 19 90 0B B E EN N Installation Guide Head Pressure Control Kit Odyssey Split System with Symbio Controls 13 to 25 Tons B BA AY YL LO OA AM MS S2 20 0 TTA156 180 201 240 251 300 TWA156 180 201 240 MOTOR ON OFF N O OK LINE 120 600VAC P N ICM334 LF MAD...

Page 2: ...ar r p pr ro op pe er r P PP PE E f fo or r t th he e j jo ob b b be ei in ng g u un nd de er rt ta ak ke en n c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s se er ri io ou us s i in nj ju ur ry y T Te ec ch hn ni ic ci ia an ns s i in n o or rd de er r t to o p pr ro ot te ec ct t t th he em ms se el lv ve es s f fr ro om m p po ot te en nt ti ia al l e el le ec ct tr ri ic ca...

Page 3: ...an nd dl li in ng g e et tc c W Wh he er re e l lo oc ca al l r re eg gu ul la at ti io on ns s a ar re e m mo or re e s st tr ri in ng ge en nt t t th ha an n t th he es se e p po ol li ic ci ie es s t th ho os se e r re eg gu ul la at ti io on ns s s su up pe er rs se ed de e t th he es se e p po ol li ic ci ie es s N No on n T Tr ra an ne e p pe er rs so on nn ne el l s sh ho ou ul ld d a al lw...

Page 4: ...s List 5 General Information 6 Disable Evaporator Defrost Control 6 Installation 7 Controller 7 Transducer and Tee 9 Wiring 9 Control Box Wiring 9 Controller Settings 15 Operation and Troubleshooting 17 Checkout Procedure 17 Table of Contents ...

Page 5: ...dge Protector 5 4 Screw 8 32 X 1 25 Pan Head 6 4 Screw 10 16 X 50 Hex Head 7 1 Label Information BAYLOAMS20 8 2 Tee Pressure Tap 9 2 Bracket Support 10 2 Harness Low Ambient Kit SOV Item Number Quantity Description 11 1 Harness 2 Kits Jumper 12 1 Harness 24V UC Board to Loam 13 2 Harness Power 14 2 Transducer 15 2 Controller Low Ambient 16 1 Supplemental Wiring Diagram 17 1 Installation Guide 18 1...

Page 6: ...rost Control I Im mp po or rt ta an nt t For proper operation of the low ambient head pressure control accessory in an Odyssey condenser the Evaporator Defrost Control EDC function MUST be disabled To disable the EDC navigate to the Utilities menu on the Symbio 700 user interface and change the configuration parameter Evaporator Defrost Control to Disabled The Symbio Service and Installation mobil...

Page 7: ...d p pe er r N NF FP PA A 7 70 0E E t th ha at t a al ll l c ca ap pa ac ci it to or rs s h ha av ve e d di is sc ch ha ar rg ge ed d W WA AR RN NI IN NG G P Pr ro op pe er r F Fi ie el ld d W Wi ir ri in ng g a an nd d G Gr ro ou un nd di in ng g R Re eq qu ui ir re ed d F Fa ai il lu ur re e t to o f fo ol ll lo ow w c co od de e c co ou ul ld d r re es su ul lt t i in n d de ea at th h o or r s ...

Page 8: ...CC SVN190B EN Figure 3 Removing the plug screws Remove Screws Figure 4 Mounting the controller Edge Protector Edge Protector Edge Protector Figure 5 Mounted controller I In ns st ta al ll la at ti io on n ...

Page 9: ...d N No ot te e If the high pressure service port is on another Tee refer to Figure 8 p 9 for connection Figure 8 Tee and transducer installed on high pressure service port 4 Tighten flare nut securely to the high pressure service port and check for leaks Wiring N NO OT TI IC CE E W Wi ir re e D Da am ma ag ge e F Fa ai il lu ur re e t to o f fo ol ll lo ow w i in ns st tr ru uc ct ti io on ns s b ...

Page 10: ... in kit harness by making an in line connection Securely attach this in line connection to adjacent wiring with wire ties See Figure 11 p 12 c Connect terminal with black and orange wires to the open tab on SOV1 See Figure 11 p 12 d Connect orange wire with stripped end to Rev valve terminal on low amb controller 1 See Figure 11 p 12 4 FOR HEAT PUMP UNITS ONLY connect Switchover valve 2 SOV2 harne...

Page 11: ...4 gauge wire harness Yellow T3 Orange T2 Brown T1 Brown to Fan Orange to Fan Yellow to Fan Yellow T3 Yellow L3 Orange T2 Orange L2 Brown T1 Brown L1 Low Ambient Controller Brown Yellow Orange Fan Harness I In ns st ta al ll la at ti io on n ...

Page 12: ...er valve connections 1 Switch Over Valve SOV 1 Black Blue Switch Over Valve SOV2 Figure 11 Switch over connections Black Blue Orange Switch Over Valve SOV1 Switch Over Valve SOV2 Orange Orange Rev Valve I In ns st ta al ll la at ti io on n ...

Page 13: ...ACC SVN190B EN 13 Figure 12 Jumper harness Low Ambient Controller Red Wire Black Wire Figure 13 Installing 24VAC harness Low Ambient Controller Red Wire Black Wire I In ns st ta al ll la at ti io on n ...

Page 14: ...14 ACC SVN190B EN Figure 14 Transducer wires Low Ambient Controller Transducer Transducer Low Ambient Controller Black Red Blue White or Green I In ns st ta al ll la at ti io on n ...

Page 15: ...MP N O T AMBIENT P1 P2 RED P2 B W G P1 B W G Y1 Y2 T STAT 24 VAC COMMON Y2 N O Jumper Position for TWA Models Heat Pump For heat pump applications the heat pump select jumper must be in the N C position see Figure 17 p 15 Figure 17 Jumper position for TWA N C C Y1 REV VALVE P1 P2 BLK HEAT PUMP N O T AMBIENT P1 P2 RED P2 B W G P1 B W G Y1 Y2 T STAT 24 VAC COMMON Y2 N C Operation The low ambient con...

Page 16: ...OF CONDUCTORS FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT CAUTION UTILICE ÚNICAMENTE CONDUCTORES DE COBRE LAS TERMINALES DE LA UNIDAD NO ESTÁN DISEÑADAS PARA ACEPTAR OTROS TIPOS DE CONDUCTORES SI NO LO HACE PUEDE OCASIONAR DAÑO AL EQUIPO N UTILISER QUE DES CONDUCTEURS EN CUIVRE LES BORNES DE L UNITÉ NE SONT PAS CONÇUES POUR RECEVOIR D AUTRES TYPES DE CONDUCTEURS L UTILISATION DE TOUT AUTRE ...

Page 17: ... r o ot th he er r i in nd di iv vi id du ua al l w wh ho o h ha as s b be ee en n t tr ra ai in ne ed d i in n h ha an nd dl li in ng g l li iv ve e e el le ec ct tr ri ic ca al l c co om mp po on ne en nt ts s p pe er rf fo or rm m t th he es se e t ta as sk ks s Before leaving the installation observe for correct operation through the desired pressure range see Table 3 p 18 Table 2 Troubleshoot...

Page 18: ...able 3 Pressure vs voltage Pressure psig Voltage Vdc 0 0 5 50 0 9 100 1 3 150 1 7 200 2 1 250 2 5 300 2 9 350 3 3 400 3 7 450 4 1 500 4 5 O Op pe er ra at ti io on n a an nd d T Tr ro ou ub bl le es sh ho oo ot ti in ng g ...

Page 19: ...ACC SVN190B EN 19 N No ot te es s ...

Page 20: ...lease visit trane com or americanstandardair com Trane and American Standard have a policy of continuous product and product data improvement and reserve the right to change design and specifications without notice We are committed to using environmentally conscious print practices ACC SVN190B EN 20 Aug 2021 Supersedes ACC SVN190A EN March 2020 2021 ...