en
29
STERYLIS ULTRA Operating Manual
The room ozonisation process must be carried out according to the following instructions. Before starting
to ozone, read the rest of this manual and meet all the safety requirements described at the beginning of
this document.
1)
Prepare the room according to the instructions below:
(a) Clean the room - vacuum, ventilate, clean from any spills.
(b) Move the furniture away from the walls, open the cabinets and empty them.
(c)
Remove all plants and animals (except fish in the aquarium) from the room.
(d) Take out or seal with foil valuable objects such as works of art, electronics.
(e) Tightly close all escape routes of ozone from the room - (windows, doors). Gaps around and under
doors and ventilation grilles must be sealed carefully.
(f)
Make sure that no one is in the rooms adjacent to the sterilised room
2)
Prepare the device for sterilisation mode - replace the activated carbon filter with a standard filter in
accordance with the filter replacement instructions.
3)
Place the unit on a stable surface and as close to the centre of the room as possible. You can put it
above the floor. In such a case secure it from falling.
4)
Place the warning sign „WARNING! NO ENTRY! OZONING IN PROGRESS”. If the room has other
possible entrances, also place this sign on them in a visible place.
5)
Connect the unit to the mains (voltage of 230 V, frequency of 50 Hz).
6)
Switch the main switch on the control panel to the „ON” position.
7)
Make sure that the device does not indicate any alarms (malfunction or need to replace
components)
8)
Start the „O3 sterilisation” mode according to the instructions in section 6.3.4.
9)
Exit the room by closing the door behind you and make sure again that it is tightly sealed and that
no one is in the room immediately adjacent to the ozone room.
10) The ozoning process has begun. Its duration is determined by the controller based on the current
ozone concentration in the sterilised room. During the ozoning it is forbidden to enter the room.
In extremely exceptional cases, where it is necessary to enter such a room, it is necessary to wear
a full respiratory and eye mask with an appropriate absorber (in accordance with EN 136 and EN
14387 standards).
11) During the ozonisation process, the device generates a light signal (using a warning beacon) and an
acoustic signal (using a buzzer) - if not already deactivated.
12) The ozoning process will be completed when the green safety ozone LED comes on. It is possible
not to reach the threshold concentration of ozone in a room (2 ppm) if its volume is too high. In this
case, after 120 minutes from the start of the ozoning process, the device will display an error, go to
the waiting phase and then after 30 minutes go to ozone neutralisation with UV lamps.
13) Once the ozone process is complete and you have made sure that the green safety ozone lamp
is active, you can enter the room to ventilate it. The room must be ventilated for a minimum of
30 minutes by providing a supply of fresh air from outside. It is forbidden to stay in the room during
ventilation.
14) Once the ventilation is complete, the room can be considered as completely safe.
Notes:
Fog may form during the ozoning. This is a normal phenomenon caused by the reaction of ozone
with volatile organic compounds. The odour of ozone persisting after the ozoning process does not
indicate its presence.
Maintenance
Summary of Contents for STERYLIS ULTRA-220
Page 2: ......