STERYLIS ULTRA Operating Manual
Product features
Purpose
Product description
The product is designed for air cleaning and disinfection and surface disinfection. Depending on the mode
of operation, it can work as a standard air purifier, an air purifier extended by sterilisation lamps with UV-C
light source and as an ozoniser. The maximum cubic capacity of the room in which the product can work is
given in the technical characteristics of the product for each model.
STERYLIS ULTRA room steriliser is a device consisting of air filters, UV-C lamps, ozone generators, fan(s),
controller together with a user panel containing segmented and graphic displays and a backlit panel. The
whole device is closed in a housing made of stainless steel, powder coated on the outside. The device is
also equipped with a flashing warning lamp (beacon), a lamp indicating safe concentration of ozone in the
room and a piezoelectric buzzer. The device can operate in several different operating modes.
In filter mode, the room air is cleaned with a pre-filter (F1) and an activated carbon filter (F2). A pre-filter
with electrostatic properties traps particles of harmful pollutants, including those of microscopic size (se-
veral micrometers). It also removes harmful bacteria and allergens using a coating applied to the filter me-
dium. In addition to particles, the active carbon filter retains harmful gases and odours through adsorption.
In the UV-C disinfection mode the UV-C lamps between the two filters are activated. The lamps emit UV-C
radiation with a wavelength of 253.7 nm and power depending on the size of the device (see technical
data). UV-C radiation irreversibly inactivates viruses, bacteria, fungi, moulds and yeasts. The Sterylis
steriliser has been designed in such a way that people can stay inside when the device is in disinfection
mode with the UV-C light source switched on. The UV-C radiation that breaks down the DNA is enclosed in
a specially designed light trap so that not even the smallest part of it can escape outside the device.
In the silent disinfection mode, the unit operates in a similar way to the standard mode, but with reduced
fan capacity. This results in a significantly reduced sound power level of the steriliser.
In sterilisation mode fan(s), filters and ozone generators are operating. This mode is used to sterilise the
air and surfaces that come into contact with the air by generating ozone evenly throughout the room. The
capacity of the ozone generator varies depending on the version (see technical data). This mode requires
special precautions to be taken by the user and proper preparation of the room for the ozone process (see:
Chapter „Important safety instructions” and „Procedure for carrying out the ozoning process”).
ULTRA STERILIS is available in 4 versions, whose technical parameters are shown in the table:
Name
STERYLIS
STERYLIS
STERYLIS
Model
ULTRA-220
ULTRA-330
ULTRA-440
Rated voltage
230 V
230 V
230 V
Frequency
50 Hz
50 Hz
50 Hz
Rated power*
470 W
670 W
810 W
Rated current*
2.0 A
2.9 A
3.5 A.
Maximum airflow capacity
290 m
3
/h
410 m
3
/h
900 m
3
/h
Types of air filters
F-1: IGL 095-902
F-2: IGL 095-903
F-1: IGL 095-904
F-2: IGL 095-905
F-1: IGL 095-902
F-2: IGL 095-903
Number of UV-C sources / Model
4 / IGL 012-217
6 / IGL 012-217
8 / IGL 012-217
UV-C wavelength
253,7 nm
253.7 nm
253.7 nm
UV-C source standard
EN 61195
EN 61195
EN 61195
UV-C source electrical power
220 W
330 W
440 W
UV-C source radiated power
78 W
118 W
157 W
Maximum UV-C radiation dose
367 J/m
2
409 J/m
2
415 J/m
2
Ozone generator capacity
20,000 mg/h
30,000 mg/h
30,000 mg/h
Net weight
26 kg
36 kg
48 kg
*in sterilisation mode