Ice Cream/ Gelato

 

 

 
Diode 8 – Defrost: Pressing this button alone:

 more than 3 sec. activates/deactivates the defrost. 

Pressing with 

other buttons:

 pressed together with 6 activates/deactivates the continuous cycle, 

Start Up:

 hold for 1 sec. displays 

firmware version. 

 
SETTING THE DESIRED TEMPERATURE 

- Press the set button  

  for 1 second leading value shall be displayed on the screen  

- Increase or decrease the leading value by means of             and            , until the desired value shall be obtained; 

- Press the set button  

 once again in order to confirm the new value of the setting point. 

 

MANUAL INPUT OF THE DEFROSTING CYCLE 

Defrosting shall be released in an automatic mode. It is possible to force defrosting at any moment by pressing and 
holding the 

      defrost switch for minimum 5 seconds. 

 

Table 3 Table of alarms and signals 

alarm code 

buzzer and alarm 

relay 

LED 

alarm description 

reset 

E0 

active 

ON 

probe 1 error= control 

automatic 

E1 

active 

ON 

probe 2 error= defrost 

automatic 

E2 

active 

ON 

probe 3 error= 

condenser/product 

automatic 

EE 

active 

ON 

unit parameter error 

not possible 

EF 

active 

ON 

operating parameter error 

manual 

Ed

 

not active

 

ON

 

defrost ended by timeout 

On first defrost ended correctly 

CHt 

active 

ON 

dirty condenser alarm 

manual 

MODIFYING THE PARAMETERS  

Parameter navigation 

The operating parameters, modifiable using the keypad, are divided into two types: frequent (type F) and 
configuration (type C). Access to the latter is protected by password (default= 22) to prevent accidental or 
unauthorized modifications. 

Accessing the type F parameters: 

-Press the SET button for more than 3 s (if there are active alarms, mute the buzzers). The display shows the 
parameter code ‘PS’ (password); 

Summary of Contents for ARB2F Series

Page 1: ...ce Cream Gelato Cases Models ARBF ARB2F series ARBF ARB2F ARBTF ARB2TF Instruction Manual Tel 416 663 3051 Fax 416 663 5793 Toll Free 1 888 408 8819 124 Norfinch Dr Toronto ON M3N 1X1 REFRIGERATION LT...

Page 2: ...nce 12 6 SERVICE 13 6 1 Faults identification and repair 13 6 2 Service 14 List of Figures Figure 1 ARBF ARB2F Overview 4 Figure 2 ARBF Layout of containers 4 Figure 3 ARB2F Layout of containers 4 Fig...

Page 3: ...ending on the environment of the unit location 2 2 Description of the unit ARBF and ARB2F display units have dynamic cooling The display cases are equipped with automatic defrosting and automatic cond...

Page 4: ...ing legs 5 Stainless steel work top 6 Stainless steel containers 7 Side glass 8 Serial plate 9 Control panel 10 Top shelf night curtain 11 Night curtain handle 12 Condenser cover DO NOT block the air...

Page 5: ...3 PREPARING THE DEVICE FOR START UP The unit must be properly installed and located in accordance with the installation instructions before it is used 3 1 Installation requirements Always use a dedic...

Page 6: ...the unit display shelves front bumper To securely transport the equipment the unit may be shipped partially disassembled If the user received the unit partially disassembled perform the following ope...

Page 7: ...prevent problems with the start up WARNING Keep the cooling circuit away from damage Turn on the main switch Figure 6 2 The temperature on thermostat control panel PRE SET Figure 6 1 Turn on the light...

Page 8: ...oisy operation and will ensure proper water condensate outflow during defrosting After transporting the equipment wait about 2 hours before starting up The products should only be placed in the unit a...

Page 9: ...working mode is activated Diode 2 Ventilator This symbol is visible when evaporator ventilators are turned on It blinks when the actuation of the ventilators is delayed by external disengagement or w...

Page 10: ...and holding the defrost switch for minimum 5 seconds Table 3 Table of alarms and signals alarm code buzzer and alarm relay LED alarm description reset E0 active ON probe 1 error control automatic E1...

Page 11: ...lue 10 C r1 99 r3 select direct reverse operation 0 0 2 r4 night time set point delta 3 0 C 50 50 c0 compressor and fan start delay on power up 1 min 0 100 c1 minimum time between consecutive compress...

Page 12: ...lage Do not use water stream to clean the equipment only a moist cloth Do not use any sharp objects to remove dirt It is recommended to make a break in the operation once a month in order to clean the...

Page 13: ...and maintenance To prevent damage Do not allow contact of the with substances containing chlorine and or baking soda in different varieties which destroy the protective layer and components of the equ...

Page 14: ...rniture adjoining the equipment does not vibrate when self contained compressor is working A noise made by the operating device is normal The units are equipped with ventilators engines and compressor...