Working Voltage
DC 1.5V
•
Battery
1 × AAA battery(1.5V)
•
Working Current
55~65mA
•
Standby Current
9.5μA~11μA
•
Transmission Distance
Without obstacle 100m
•
Transmission Frequency
433.29MHz
•
Working Temperature
-10
℃
~40
℃
•
Humidity
≤90%rh (non-condensing)
•
Weight
32.3g(Battery not included) 43.5g(Battery included)
•
Dimension
Transmitter :80.0mm*38.2mm*13.3mm(L*W*H)
Connecting Line: 21cm
Installation Manual
|
Wireless Water Intrusion Sensor
Instalační Manuál
|
Bezdrátový detektor vody
Inštalačný Manuál
|
Bezdrôtový detektor vody
Website : www.iget.eu E-mail : [email protected]
Features
Parameters
Appearance
The iGET SECURITY M3P9 wireless water intrusion sensor is an accessory of M3/M4 series smart alarm system. It's fashion
design, energy saving, and low battery warning supported. The main panel will send a SMS to user for battery replacement
when needed. It triggers alarm when detecting water intrusion.
SECURITY M3P9
PCB Layout
Operating Instructions
Installation & Notice
Battery replacement instructions
1. Working principle
The transmitter sends trigger signal to paired main panel when the sensor detects water intrusion.
2. Pairing with main panel by App
①
Scan the QR code printed on the sensor and follow the guideline in App to continue.
②
The pairing result would be confirmed by SMS sent from main panel.
Trigger Mode Clarification
• Open the case and remove the battery insulative strip.
• Pair it with panel by App before installing.
• Attach the transmitter with the double-side sticky tape to proper positon. Avoid installing it in any area with a large amount
of metal or electric wires.
• Fix the connecting line on wall or any proper position.
• Fix the probe on detecting position. Aoivd installing it in any area with rains, heavy smoke or oil, or with heavy water vapour.
• To ensure long-term reliability, please clean and maintain the probe surface regularly.
①
Insert the flat blade of a small screwdriver into the pry-off
slot of transmitter, twist the blade to remove the cover.
Trigger Mode
Clarification
Close
Deactivated when triggered
Instant
Activated when ARM/HOME ARM
24 Hours
Activated even when DISARM
Home
Deactivated when DISARM/HOME ARM
Door Chime
No alarm but clanking
Delay
Wait few seconds before alarm
②
Replace with 1xAAA battery.
1
2
LED Indicator
Transmitter
Probe
Connecting Line