Iget SECURITY M3P10 Installation Manual Download Page 1

• 

Working Voltage

DC 1.5V

• 

Battery

1 × AAA battery(1.5V)

• 

Working Current

55~65mA

• 

Standby Current

9.5μA~11μA

• 

Transmission Distance 

Without obstacle 100m

• 

Transmission Frequency

433.29MHz

• 

Working Temperature

-20

~50

• 

Humidity

≤90%rh (non-condensing)

• 

Weight

21g(battery not included)      31.8g(battery included)  

• 

Dimension

80.0mm*38.2mm*13.3mm   L*W*H

Installation manual 

|

 

Wireless Vibration Sensor

Instalační manuál    

|

 

Detektor vibrací

Inštalačný manuál   

|

 

Detektor vibrácií

Website : www.iget.eu E-mail : [email protected]

Battery replacement instructions/ 

Výměna baterie

Výmena batérie

Trigger Mode Clarification/ 

Funkce Trigger

Funkcie Trigger

Trigger Mode Mód Triggeru Mód Triggeru

Clarification

 Význam

Význam

Close

Zavřený

Zatvorený

Deactivated when triggered 

Deaktivován pro všechny režimy alarmu

Deaktivovaný pre všetky režimy alarmu

Instant

Okamžitý

Okamžitý

Activated when ARM/HOME ARM

Aktivní když je režim alarmu Aktivován/

Režim Doma

Aktívny keď je režim alarmu Aktivovaný / 

Režim Doma

24 Hours

24 Hodin

24 Hodín

Activated even when DISARM

Aktivní vždy i při režimu alarmu Deaktivace

Aktívna vždy aj pri režime alarmu 

Deaktivácia

Home

Režim Doma

Režim Doma

Deactivated when DISARM/HOME ARM

Neaktivní pokud je režim alarmu Deaktivace/

Režim Doma

Neaktívne ak je režim alarmu Deaktivácia / 

Režim Doma

Door Chime

Uvítací Gong

Uvítací Gong

No alarm but clanking

Bez alarmu, ale uvítací gong (např. pro 

obchody)

Bez alarmu, ale uvítací gong (napr. pre 

obchody)

Delay

Zpoždění

Oneskorenie

Wait few seconds before alarm

Čeká několik vteřin před aktivací alarmu

Čaká niekoľko sekúnd pred aktiváciou 

alarmu

Insert the flat blade of a small screwdriver into the pry-off slot of transmitter, 

twist the blade to remove the cover.

Stiskněte tlačítko dolů pomocí palce a druhou rukou otevřete kryt detektoru.

Stlačte tlačidlo nadol pomocou palca a druhou rukou otvorte kryt detektora.

Replace with 1xAAA battery.

Vyměňte 1xAAA baterii.

Vymeňte 2x AA batérie.

Features

Parameters

Appearance

The M3P10 wireless vibration sensor is an accessory of iGET SECURITY M3 series smart alarm system.
It’s fashion design, energy saving, low battery alert supported and with long transmission distance. The main panel will send
a SMS to user for battery replacement when needed. It sends trigger signal to main panel when detects vibration. It’s ideal
for security of safes, drawers, doors and windows.

SECURITY M3P10

Exclusive importer of products Shenzhen Dinsafe Intelligence Co., Ltd. 
for the Czech Republic and Slovak Republic
INTELEK spol. s.r.o., Vlárská 22, 627 00 Brno
SUPPORT: http: //www.iget.eu/helpdesk
Copyright © 2015 INTELEK spol. s r.o. All rights reserved.

LED Indication

LED flashes once: 

Door/window is opened and transmitter sends signal to the main panel. 

LED lights stays on: 

Low battery, please replace the battery immediately.

LED Indicator

PCB Layout

Operating Instructions

Installation & Notice

1. Working principle
The transmitter sends trigger signal to main panel paired when the magnet mounted near is moved apart. 
2. Pairing with main panel by App

Scan the QR code printed on the sensor.

The pairing result would be confirmed by SMS sent from main panel.

• 

Open the case and remove the battery insulative strip.

• 

Pairing with main panel by App before installing. 

• 

Attach the sensor with the double-side sticky tape to safes, drawers, doors and windows.  

Reviews: