19
iG5 User Manual
Green
Blinks green when the receiver is fixed and
correction data is received.
Files
Amber
Blinks each time a data epoch is stored to
a static file.
Push and hold the Files button for 10-seconds
to toggle data recording ON and OFF.
The LED blinks when recording is active.
Secret Reset Mainboard Mode
With the receiver turned ON, push and hold the Files button
while clicking the Power button 5-times. This will initialize the
OEM receiver engine.
Recording Rate
The iG5 receiver is configured to automatically record raw
files with a 1 Hz rate.
The receiver has 6,741,970,900 bytes available for user
observation files. The receiver will generate approximately 14
MB per hour with normal constellations at 1Hz so
approximately 481 hours (20 24-hour days) of continuous
data can be stored on the receiver.
If you need to store data longer without downloading, you
can set the recording rate to 5-seconds or 30-seconds.
The receiver is set to automatically delete the oldest file (Ring
Buffer) as needed to record new files which will overwrite the
oldest files on the receiver.