Smoke Pipe Instructioons
•
Horizantal chimney's duct and vertical chimney's pipe connections are very
important, therefore, it must be done carefully. Warranty of the smoke pipe
connection should be made accordingly.
•
The minimum safety opening surface sections should be 15%. Slope in the
horizontal section of the pipe should be 3-5%. (3-5 cm per meter). The horizantal
chimney's duct should not be longer than 2 m.
•
The boiler chimney pipe inner diameter is 100 mm.
•
Horizantal chimney's duct and vertical chimney's pipe should be made of durable
materials for heat, corrosion and condensation.
•
Please take care of flue pipe standart sizes, the problems in case of using
nonstandard sizes will not be under our responsibility.