59
4.3.3
Anti Condensation Valve Connection Schema
Anti condensate valve; By automatically adjusting the temperature of the water
entering the boiler to the calibration value (55
⁰
C), it prevents the condensation
of water vapor in the smoke.
Anti condensate valve is a system in which the boiler is circulated to the outlet
water to bring it to the appropriate temperature. In order to check the
temperature of the water entering the solid-fueled boiler during and after the
first start-up phase, it performs a mixing operation between the inlet water and
the leaving water.
4.3.1. GT15 and 4.3.2. GT25 Plumbing Installation Schema are shown
“
Anti-condensation valve connection
”
details.
Connection Locations;
A - Radiator Cold Water Return Line
B - Boiler Hot Water Outlet Line
AB - Boiler Cold Water Return Line
Assembly and dismantling;
it should always be carried out when
the system is cold and unpressurized.
Access;
valve access must be not prevented in order to allow
maintenance of valves or piping equipment.
Warranty Coverage Warning;
As the anticondensation valve is used, it is necessary to use
heating circulating pump and gate valve.The product is not covered
by the warranty when the Anti-Condensation valve isn't use.
4.3.4
Heating Circulation Pump
The heating circulating pump with the same values as the circulating pump
values should be used.
Summary of Contents for GT-15
Page 1: ...0 2019 PELET KAZANI KULLANMA KILAVUZU PELLET BOILER USERGUIDE Rev No 2019 1 1...
Page 2: ...1...
Page 29: ...28 8 TEMEL PAR ALAR VE BOYUTLAR Model GT 15...
Page 31: ...30 Model GT 25...
Page 33: ...9 BA LANTI EMALARI 9 1 Anakart Model GT 15 GT 25...
Page 74: ...73 8 MAIN PARTS AND DIAMENTIONS Model GT 15...
Page 76: ...75 Model GT 25...
Page 78: ...9 CONNECTION SCHEMAS 9 1 Mainboard Model GT 15 GT 25...
Page 98: ......
Page 99: ......