3

ZZ1102 I/O module

UK

2  Safety instructions

 

The devices described are subcomponents for integration into a system� 

 

– The operator is responsible for the safety of the system�

 

– The system architect undertakes to perform a risk assessment and to create documentation in 

accordance with legal and normative requirements to be provided to the operator and user of the 

system� This documentation must contain all necessary information and safety instructions for the 

operator, the user and, if applicable, for any service personnel authorised by the architect of the 

system�

 

– The system manufacturer is responsible for the proper functioning of the application programs�

 

Read this document before setting up the devices and keep it during the entire service life�

 

The devices must be suitable for the corresponding applications and environmental conditions without 

any restrictions�

 

● Use the devices for their intended purpose (→ „3 Functions and features“).

 

If the operating instructions or the technical data are not adhered to, personal injury and/or damage to 

property may occur� 

 

The manufacturer assumes no liability or warranty for any consequences caused by tampering with 

the devices or incorrect use by the operator�

 

Installation, electrical connection, set-up, programming, configuration, operation and maintenance of 

the devices must be carried out by personnel qualified and authorised for the respective activity�

 

Protect units and cables against damage� 

 

Because of the requirements for electromagnetic interference emissions, the devices are intended for 

use in industrial environments� The devices are not suitable for use in domestic areas�

WARNING

If the set is used for operator protection, death or serious irreversible injuries are possible�
The set is an assistance system and only supports the recognition of objects� The operator of 

the system bears full responsibility for persons within the area monitoring�

 

Only use the set for support as an assistance system�

3  Functions and features

The ZZ1102 set digitises all kinds of input signals for the O3M 3D sensor� Moreover, the output signals of 

the O3M 3D sensor can be processed in an analogue or digital way�
For this purpose, the BasicController included in the set is operated with the supplied CAN/power adapter 

cable�

Summary of Contents for ZZ1102

Page 1: ...Instructions for set up O3M I O module ZZ1102 80282602 00 04 2020 UK A B C D E F N P N ...

Page 2: ...nd further information at www ifm com You will find detailed instructions technical data approvals and further information using the QR code on the unit packaging or at www ifm com 1 1 Symbols used Instruction Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings...

Page 3: ... or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the devices or incorrect use by the operator Installation electrical connection set up programming configuration operation and maintenance of the devices must be carried out by personnel qualified and authorised for the respective activity Protect units and cables agains...

Page 4: ...6 connection cable with contact housing for BasicController inputs 2x EC9207 connection cable with contact housing for BasicController outputs 1 x instructions for set up 5 Function The BasicController included in the set is supplied with voltage and connected to the O3M 3D sensor via the CAN power adapter cable The O3M 3D sensor communicates with the BasicController via the CAN bus The BasicContr...

Page 5: ...120 s For the correct rating of the overcurrent protection device take the technical data of the device and wiring into account The separation of external circuits must comply with UL 61010 2 201 Figure 102 Disconnect power before connecting the device For cable lengths 30 m use an additional protection against surge voltages to IEC 61000 4 5 The IP rating indicated in the data sheet is only guara...

Page 6: ... via 6 3 x 0 8 mm blade male terminals on the front of the BasicController Block C inputs and Block F outputs are pre programmed Connect the BasicController via these terminal strips 7 2 1 The BasicController features an application specific configuration The configuration is also used as part of application packages e g O3M Area Surveilliance ZZ1103 N2 2 3 1 A B C D E F N2 P N1 Inputs A B C Outpu...

Page 7: ... 01 binary output inverted linked with logic O3M digital output 72 OUT 02 binary output inverted linked with logic O3M digital output 73 OUT 03 binary output inverted linked with logic O3M digital output 74 E OUT 04 binary output inverted linked with logic O3M digital output 75 OUT 05 binary linked with logic O3M digital output 76 OUT 06 binary linked with logic O3M digital output 77 OUT 07 binary...

Page 8: ...s available for download www ifm com 7 2 1 Connect BasicController A B C D E F N2 P N1 Connect cable Connect CAN power adapter cable to P N1 Plug EC9206 connection cable with contact housing onto input strip C Plug EC9207 connection cable with contact housing into output strip F If necessary plug the second EC9207 connection cable onto output strip D or E A B C D E F N2 P N1 LED Mount cable seal o...

Page 9: ...ovided in the BasicController Press the cover on Move the locking lever 1 back into its initial position C Inputs F Outputs Connect the M12 connector of the CAN power adapter cable to the O3M 3D sensor 7 1 Connect the two twisted wires of the CAN power adapter cable to a power supply Blue GND brown L 24 V Assign the lines to the inputs and outputs of the BasicController as required Take pre progra...

Page 10: ...t e g BUSOFF 250 ms 250 ms 250 ms 250 ms 250 ms 250 ms 250 ms 250 ms System runs normally standard IO module 1500 ms 500 ms System runs normally configured IO module 1500 ms 50 450 ms Device incompatible or not working 1500 ms 500 ms Connection establishment O3M 3D sensor not accessible 150 ms 100 150 ms 100 150 ms 100 150 ms 1100 ms Calibration active O3M 3D sensor not accessible 150 ms 100 150 m...

Page 11: ...ED calibration connection establishment etc Table 2 LED indication of the operating states 9 Set up The BasicController is pre programmed for the application 7 2 Table 1 and can be put into operation directly after installation and electrical connection If further input and output signals are required they can be defined in the logic of the O3M 3D sensor with the help of ifm Vision Assistant ...

Reviews: