12
1
3
2
4
5
The following applies to units with 3-A
certification:
►
Only use adapters with 3-A
certification for the process
connection�
►
Do not install the unit at the lowest
point of the pipe or tank (→ position
5) in order that the medium can run
off the area of the sensor elements�
6.2 Use in hygienic areas to EHEDG
The sensor is suited for CIP (cleaning in process) when installed correctly�
►
Observe the application limits (temperature and material resistance)
according to the data sheet�
►
Make sure that the sensor is integrated into the system according to EHEDG�
►
Use self-draining installation�
►
Only use process adapters permitted according to EHEDG with special seals
required by the EHEDG position paper�
The gasket of the system interface must not be in contact with the
sealing point of the sensor�
►
In case of structures in a tank, the installation must be flush mount� If not
possible then direct water jet cleaning and cleaning of dead spaces must be
possible�
►
Leakage ports must be clearly visible and must be installed facing downwards
for vertical pipes�
►
Adhere to the dimensions shown in Fig� 1 to avoid dead space: L < (D - d)�