SBZ224
Mechatronic flow sensor
12
5 Mounting
CAUTION
During installation or in case of a fault (e.g. housing damage) media under high pressure or
hot media can leak from the system.
w
Risk of injury caused by pressure or burns.
u
Ensure that the system is free of pressure during installation.
u
Ensure that no media can leak at the mounting location during installation.
u
Equip the unit with suitable protection (e.g. cover) to avoid hazard to personnel from
leaking media.
5.1 Process connection
u
Avoid major changes of cross section on the inlet side.
IN
OUT
Fig. 9: Process connection
IN:
Inlet
OUT:
Outlet
Calming sections on the sensor's inlet or outlet side are not necessary.
The sensor can also prevent backflow.
The sensor head can be rotated by 360°.
5.2 Interference
u
The following minimum distances must be adhered to:
Distance between the sensor and ferromagnetic materials
≥ 30 mm *
Distance between the sensor and constant / alternating fields
≥ 500 mm
Distance between the sensor axes for side-by-side installation
≥ 50 mm