4

2 Safety instructions

The unit described is a subcomponent for integration into a system.

– The system architect is responsible for the safety of the system.

– The system architect undertakes to perform a risk assessment and to create documentation in

accordance with legal and normative requirements to be provided to the operator and user of
the system. This documentation must contain all necessary information and safety instructions
for the operator, the user and, if applicable, for any service personnel authorised by the
architect of the system.

Read this document before setting up the product and keep it during the entire service life.

The product must be suitable for the corresponding applications and environmental conditions
without any restrictions.

Only use the product for its intended purpose (

Ò

 Intended use).

If the operating instructions or the technical data are not adhered to, personal injury and/or damage
to property may occur.

The manufacturer assumes no liability or warranty for any consequences caused by tampering with
the product or incorrect use by the operator.

Installation, electrical connection, set-up, operation and maintenance of the product must be
carried out by qualified personnel authorised by the machine operator.

Protect units and cables against damage.

Summary of Contents for RN6065

Page 1: ...Operating instructions Absolute encoders with SSI interface RN6065 RN6066 11437085 00 02 2022 GB...

Page 2: ...fety instructions 4 3 Intended use 5 4 Installation 6 5 Electrical connection 7 5 1 Cable connection 7 5 2 Wiring with standard configuration 7 6 Operation 8 6 1 Data signals 8 6 1 1 Triggering of a d...

Page 3: ...e RN6065 RN6066 3 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interfer...

Page 4: ...by the architect of the system Read this document before setting up the product and keep it during the entire service life The product must be suitable for the corresponding applications and environme...

Page 5: ...position of the revolutions is provided as a numerical value These values allow angular movements to be measured and positions and number of revolutions to be determined Supply voltage and resolution...

Page 6: ...similar tool on the shaft risk of destruction u Avoid damage to the shaft and the bearing u Connect encoder and drive by means of a flexible coupling u In case of linear measurement with a measuring w...

Page 7: ...length 100 m u Install the unit separately from interfering sources minimum distance 0 2 m u Connect the encoder housing the connector terminal box and the evaluation electronics via the screen 5 2 W...

Page 8: ...y to transmit the next measured value If during this time there is a new request for data output clock the data which have already been provided are provided again In this case the data output is low...

Page 9: ...6 9 Reset to zero To use the function Reset to zero the shaft has to be stopped A reset to zero when the shaft is rotating can lead to incorrect position values By application of L to pin 2 for at lea...

Page 10: ...ee u Contact ifm in case of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u C...

Reviews: