9.6.2 Reading the overload processes
• HIPC: Number of overload processes
HIPC counts how often the HIPS threshold has been exceeded�
The value must exceed the threshold for at least 0�5 ms�
• HIPS: Setting of the threshold for the overload counter�
The parameters HIPC and HIPS are only available via IO-Link
communication�
10 Operation
After power on, the unit is in the RUN mode (= normal operating mode)� It carries
out its measurement and evaluation functions and provides output signals
according to the set parameters�
Operation indication
(→ 7 Operating and display elements)
�
10.1 Read the set parameters
► Press [●]
►
Press [
▲
] or [
▼
] until the required parameter is displayed�
► Briefly press [●].
> The unit displays the corresponding parameter value for approx� 30 s; then it
changes to the process value display�